Troubleshooting
Problem | Possible Cause | Solution | |
|
|
| |
| There was a power failure | Restore the power supply | |
| The plug is not correctly inserted | Insert the plug correctly into the | |
| into the socket | socket | |
|
| Flip the switch, change the fuse, | |
|
| or turn the breaker back on. Also | |
| The automatic switch, line fuse, | note that you may have too many | |
| or breaker has been tripped | appliances drawing power on one | |
The portable air conditioner does |
| circuit, so you may need to move | |
not turn on |
| some onto another circuit | |
| The power supply voltage is too | Move the unit onto another | |
| low | circuit with the correct voltage | |
|
| Call for service. Only authorized | |
| The power cord is damaged | service man should replace | |
|
| damaged plugs | |
| The LCDI plug for the unit is | Press the Reset button on the | |
| tripped | portable air conditioner's plug | |
| The room temperature is outside | This unit is designed to work in | |
| of the operational tolerances of | ambient temperatures of 64°F to | |
| the unit | 100°F | |
|
| Press the Mode button until the | |
| The Cooling mode is not on | Cooling icon is shown on the | |
|
| control panel | |
The unit turns on, but the | The compressor has not turned | Give the compressor 3 minutes to | |
turn on after the Cooling mode | |||
compressor does not turn on- the | on yet because of its time delay | ||
has been selected | |||
fan runs, but there is no cooling |
| ||
The set temperature is too high | Reset the temperature lower | ||
| |||
|
| Check the water level indicator | |
|
| on the control panel. If it is lit, | |
| The internal water reservoir is | either manually drain the water | |
| full | or allow the unit to exhaust the | |
|
| water itself. Then cooling will | |
|
| resume | |
The air coming out of the unit is | The filter is dirty or obstructed | Clean the filter | |
not very cold, or the airflow |
| Make sure there is at least 20" of | |
volume is weak | The air intake is obstructed | clearance from the air intake (on | |
|
| the front of the unit) | |
| The exhaust duct is too long | Make the exhaust duct as short as | |
| possible | ||
|
|
17