Oreck 2005RH, 2005HH warranty Stuffing or Blockage, Retainer Spring

Page 7

To Adjust or Replace Brush

WARNING: Unplug cord from electrical outlet before servicing.

Stuffing or Blockage

Under certain conditions it is possible to stuff or block the intake tube and the lower tube assembly. If your vacuum cleaner does not pick up properly, or makes unusual noise and the outer bag

To determine if the brush is worn, place a firm straight edge across the nozzle opening. If brush bristles

does not fluff up or balloon open, follow the following steps:

WARNING: Unplug cord from electrical outlet before servicing.

Rotate and match

bearing assemblies

do not extend beyond baseplate, brush should be adjusted.

Remove the baseplate by removing 5 screws. Then, remove the belt and brush roll from the housing.

Rotate both bearing assem- blies at ends of brush roll to show “OLD” and replace in the holding channels in the housing.

NOTE: The bearing assembly setting marked “OLD” has a smooth side. The one marked “NEW” has a notch. When rotating bearings, make sure both bearing assembly settings are the same and face up when replacing the brush roll.

A

Intake Opening

Retainer

 

Spring

 

 

C

 

Fan

 

Housing

O-ring

 

1.

Check for blockage at the

 

mouth of the intake

 

opening. See illustration A.

 

If there is blockage, remove

 

it with long-nose pliers, a

 

screwdriver or coat hanger.

 

If you can not reach the

 

blockage, remove

 

baseplate. See illustration B.

2.

If the blockage is not at the

 

base, remove lower tube.

 

See illustration C. Unhook

 

retainer spring, releasing

 

bottom of bag. Twist lower

 

collar counterclockwise to

 

slide up. Pull tube out of

 

base. Check for blockage.

 

If blockage is in the tube,

 

remove with a coat hanger.

3.

If tube is not blocked, look

 

into fan housing. See illus-

 

tration D. Remove debris

 

with long-nose pliers, a

 

screwdriver or coat hanger.

4.

To reassemble, check O-ring

 

on tube, and replace if

 

damaged. Vacuum will not

 

operate properly without the

 

tube O-ring. Slide O-ring to

 

approximately 2" from base

IMPORTANT: Unless the brush is worn as indicated above, both bearings must be in the “NEW” position. When rotating, both bearings must be in the ”OLD” position. Unmatched settings will cause damage to your machine.

Reassemble the belt and the baseplate and check bristle height above baseplate at each end of brush.

If a previous adjustment has already been made and bristle height does not extend above baseplate, a new brush assembly should be ordered.

D

E

of tube. Replace tube by

first lining up slot at base of

tube with inner tab inside

fan housing. Then reinsert

tube and push down until

the tube is seated. Make

sure O-ring is in place

against fan housing

opening. Replace and

tighten collar until collar

locking tabs are locked in

place. See illustration E.

Make sure collar is not cross

threaded on housing.

7

Image 7
Contents 2005HH 2005RH Table of Contents Sold Separately Maintenance Customer ServiceWarranty AccessoriesHook bottom of bag collar Assembly To Replace Filter Dust BagLip a of connector InstalledOperating Instructions Celoc Hypo-Allergenic Filter System 2005HH How to Replace a Worn BeltRetainer Spring Stuffing or BlockageTroubleshooting Guide