Henkel SubFloor manual Sheet laying procedure Laying procedure for Saga

Page 3

Technical guide

Technical guide

 

 

Sheet laying procedure

Laying procedure for Saga

The sheets must be unrolled and left in the room to be covered, with the adhesive, for at least 24 hours prior to laying.

Minimum temperature must be 15 °C.

1.Lay first length along guide line, ensuring sheets are laid lengthways in the same direction as the light falls.

Beware installation directions according to pattern.

2.Fold back sheets half way.

3.Use a finely serrated trowel to apply the single stick acrylic emulsion adhesive. The adhesive manufacturer's instructions must be followed.

Insufficient open time of the adhesive will cause bubbles.

If the open time is too long the adhesive transfer will be poor.

4.Smooth down manually then roll with a 50 kg flooring roller.

5.If necessary groove and heat weld the joints after 24 hours after installation.

Do not traffic the floorcovering for 48 hours after installation.

Other cases:

Reverse lay the following products: Nera Contract, Taralay Comfort. Please note the reverse lay symbols on the packaging. Most sheet products are laid by overlapping the edges and cutting through.

Tarasafe Standard, Tarasafe Iona, Tarasafe Comfort, Tarasafe Plus, Tarasafe Ultra, Tarasafe Style, Tarasafe Super however should be laid with a 1 mm gap to allow for the grooving machine. Grooving should be done manually.

Technical

guide

172

 

 

Overall adhesion with tackifier emulsion adhesive

A gripping primer compatible with the tackifier emulsion adhesive and the subfloor must be applied before gluing.

1 - Positioning of the floor covering

The tiles should be removed from their box at least 24 hours before laying and placed in the room in which they are to be used

2 - Tackifier emulsion adhesive

The tackifier emulsion is applied in a single coat:

using a finely notched trowel, quantity 100 to 150 g/m2, type A1,

using a foam roller, quantity 100 to 150 g/m2.

3 - Laying of tiles. Alignment.

A - When laying the tiles, the following points must be respected:

use whole tiles or large cut tiles (more than 50% of the original tile size), in heavy traffic zones (door thresholds, corners in corridors, waiting areas),

align a row of tiles along the main access paths,

align one of the start lines with the longest wall-to-wall direction in the room.

B - Alignment.

 

Trace a guide line along which the tiles are to be laid (see fig 1).

1

 

4 - Preparation of subfloor and laying of tiles.

 

Beware installation directions according to the pattern.

2

• Spread the tackifier emulsion adhesive over half the room.

 

• Lay the first row of tiles along the axis perpendicular to the door.

 

• Block this row in place using the wall as a support (see fig 2).

 

• Lay the following rows of tiles and block them against the first row.

1

 

Tracing the guide lines:

5 - Smoothing.

• axis perpendicular to main entrance,

• the perpendicularity of this axis is

This operation must be carried out in two stages .

balanced by the tile cuts.

 

• Smooth down manually.

2

• Roll with a 50 kg flooring roller over the entire surface.

• Starting in the middle of the room, lay

Positioning of furniture.

the tiles of the middle row. Block this

row in place using the wall

When positioning furniture, pay attention not to drag heavy objects

perpendicular to this row as a support.

over the floorcovering

• Lay the following rows of tiles and

 

block them against the first row.

173

Technical guide

 

Image 3
Contents Technical Technical guidePreparing the Subfloor General InformationSmoothness HardnessFlatness DrynessOverall adhesion with tackifier emulsion adhesive Sheet laying procedure Laying procedure for SagaMinimum temperature must be 15 C Beware installation directions according to the patternLaying procedure Laying Procedure for Residential Sheet ProductsFor residential sheet products Cold welding Hot weldingAdhesives Very LOW Maintenance Products MaintenanceSpecific Maintenance Products Residential FlooringStain Removal Table 182

SubFloor specifications

Henkel SubFloor is a revolutionary flooring solution designed to provide a robust foundation for various types of floor coverings, whether in residential or commercial spaces. Its innovative approach is driven by a commitment to quality, sustainability, and enhanced performance, which makes it a preferred choice among professionals in the construction and renovation sectors.

One of the standout features of Henkel SubFloor is its exceptional leveling capability. The product is formulated to create a smooth and even surface, which is essential for the proper installation of tiles, carpet, or hardwood flooring. This characteristic not only simplifies the flooring process but also ensures long-lasting results, as an accurately leveled subfloor minimizes the risk of cracks and other issues that can arise over time.

Henkel SubFloor incorporates advanced technologies that enhance its performance. The product contains specially formulated binders that provide superior adhesion and flexibility. These binders allow the subfloor to accommodate minor shifts and movements in the building structure without compromising its integrity. This flexibility is particularly beneficial in areas prone to temperature fluctuations and humidity changes, as it reduces the likelihood of cracking or damage over time.

Another key characteristic of Henkel SubFloor is its moisture resistance. The innovative formulation helps prevent moisture penetration from below, which is crucial in areas like basements or ground floors. This resistance to moisture not only promotes a healthier indoor environment by reducing the risk of mold and mildew but also extends the lifespan of the floor covering applied on top.

Moreover, Henkel is committed to sustainability, and the SubFloor product reflects this ethos. The formulation incorporates eco-friendly materials that reduce the overall environmental impact while ensuring performance standards are met. This focus on sustainability aligns with the increasing demand for green building products in the construction industry.

In summary, Henkel SubFloor stands out as a versatile and reliable solution for achieving a stable foundation for various flooring types. Its leveling properties, advanced adhesion technology, moisture resistance, and commitment to sustainability make it an excellent choice for both professionals and DIY enthusiasts looking for quality flooring solutions. With Henkel SubFloor, users can enjoy peace of mind knowing they are paving the way for a successful flooring project.