Heatiator NEVO4236I NEVO3630I owner manual Appliance Setup

Page 56

15 Appliance Setup

A. Remove the Packaging

Remove the shrink film, corrugated top cap, bottom cap and column protectors from the appliance. The appliance should look as shown in Figure 15.1.

Figure 15.1 Appliance Unwrapped

Pull the four glass assembly latches out of the groove on the glass frame. Refer to Figure 15.2.

Remove the glass assembly from the appliance.

Latches

 

(both bottom

 

and top)

 

Glass

 

Assembly

 

Figure 15.2

Glass Assembly

D. Remove Glass Media Package

The glass media package is shipped inside the firebox. Refer to Figure 15.1.

B. Remove the Shipping Materials

Remove the shipping materials from inside and under- neath the firebox.

C. Removing Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT:

Strike, slam or scratch glass

Operate fireplace with glass removed, cracked, broken or scratched.

Replace fixed glass assembly as a complete assembly.

E. Clean the Appliance

Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity.

F. Accessories

Install approved accessories per instructions included with the accessories. Refer to Section 17.

WARNING! Rick of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazad and will void the warranty.

56

Heatilator • Evolution • 4065-114 Rev. o • 11/11

Image 56
Contents Installation and Operation ModelsCongratulations Homeowner Reference InformationTable of Contents Finishing Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceBefore Lighting Fireplace IPI Battery Tray/Battery InstallationControl Module Operation Lighting Instructions IPI Final inspection byAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Select Appliance LocationConstruct the Appliance Chase Clearances Clearances to CombustiblesMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Two ElbowsNo Elbow Top Vent Vertical TerminationThree Elbows Install Top Vent Flue Baffle No Elbow Configu- rations 7a Remove Flue Visor12 ft 3.66 m min 60 ft 18.29 m max 12 ft 3.66 m min ft 18.29 m max Rear Vent Horizontal Termination One 45 ElbowTwo Elbows Rear Vent Vertical Termination Min Ft 1.83 m max 12 ft 3.66 m min Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and atticsVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Top VentRear Vent It Cannot be changed at a later time BasketSecure and Level the Appliance 11 Proper Positioning and Securing of an ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections DVP Only Assemble Pipe SectionsAssemble Vent Sections SLP Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap Failure to maintain overlap may cause overheating and fireShrouds HHT ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHWMailbox Style Shroud Dimensions Min. Base Dims Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements IntelliFire Plus Ignition System WiringOptional Accessories Requirements Electrical InformationElectrical Service and Repair WHTJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Marble/Granite Cut Dimensions Facing MaterialAppliance Setup Place the Glass Media Cleaning the Glass MediaInstall the Glass Media Replacing Fixed Glass Assembly Air Shutter SettingTroubleshooting Intellifire Ignition SystemGas supply Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP DVP-HRC-SS 168 mm SL-2DVP Description Part Number Service Parts NEVO3630i Stocked at DepotService Parts NEVO4236i Service Parts NEVO3630i, Nevo #13 Valve AssemblyStocked At DepotDescription Comments Part Number NEVO3630I Optional Components Catalog #Contact Information Do not Discard this Manual

NEVO4236I NEVO3630I specifications

Heatiator has made a significant mark in the world of modern heating solutions with its innovative NEVO4236I and NEVO3630I models. These versatile heating units are designed not just for efficiency but also to enhance the aesthetic appeal of any space.

The NEVO4236I and NEVO3630I both showcase sleek, contemporary designs that effortlessly blend into various interior styles. With a minimalist aesthetic, these units do not just serve as functional heaters; they also add a unique touch to the decor. The clean lines and attractive finish make them ideal for modern homes, offices, and commercial spaces.

One of the standout features of the Heatiator NEVO4236I and NEVO3630I is their advanced heating technology. Both models utilize electric heating elements that provide consistent and controlled warmth. This ensures a comfortable environment while maintaining energy efficiency. Users can enjoy rapid heat-up times, allowing spaces to reach optimal temperatures quickly without wasting energy.

In terms of user convenience, both models are equipped with smart technology features. They include programmable thermostats and remote control options, enabling users to easily adjust the temperature from anywhere in the room. This adds an extra layer of comfort and convenience, ensuring that spaces can be pre-warmed before occupants arrive.

Furthermore, safety is a critical aspect of the Heatiator NEVO4236I and NEVO3630I. Both units come with built-in safety features such as overheat protection and tip-over switches. These features provide peace of mind, particularly in homes with children or pets.

Another notable characteristic is their low noise operation. Unlike conventional heaters that can be noisy and disruptive, these models operate quietly, allowing for a tranquil environment perfect for relaxation or concentrated work.

The energy efficiency of the Heatiator NEVO4236I and NEVO3630I must not be overlooked. Designed to minimize electricity usage while maximizing heat output, they represent a sustainable choice for environmentally conscious consumers. This efficiency not only benefits the environment but also affects the energy bills positively.

In summary, the Heatiator NEVO4236I and NEVO3630I stand out for their modern design, advanced heating technologies, user-friendly features, safety measures, low noise levels, and energy efficiency. These attributes make them an excellent choice for anyone looking to enhance their heating solutions while maintaining aesthetics and functionality in their living or working spaces.