Heatiator NEVO4236I NEVO3630I Termination Locations, Vent Termination Minimum Clearances

Page 22

6 Termination Locations

A. Vent Termination Minimum Clearances

WARNING

Fire Risk.

Maintain vent clearance to combustibles as specified.

DO NOT pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause overheating and fire.

A

B

6 in. (minimum) up to 20 in.

18 in. minimum

152 mm/508 mm

457 mm

20 in. and over

0 in. minimum

Gas, Wood or Fuel Oil

Termination Cap

B

24 in. min.

(610 mm)

Termination

Cap

 

 

 

 

Horizontal

 

20 in.

 

 

overhang

 

 

 

 

 

 

 

 

 

 

(508 mm)

Vertical

Lowest

wall

Discharge

 

Opening

 

A *

Gas

Termination

Cap **

Storm Collar

 

 

12

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing

 

 

 

 

 

Roof Pitch

 

 

 

 

 

 

 

 

 

 

 

 

 

is X / 12

 

 

 

 

H (min.) - Minimum height

 

 

 

 

from roof to lowest

 

 

 

 

 

discharge opening.

 

 

Roof Pitch

H (Min.) Ft.

 

Roof Pitch

H (Min.) Ft.

Flat to 6/12

 

1.0*

 

Over 11/12 to 12/12

4.0

Over 6/12 to 7/12

1.25*

 

Over 12/12 to 14/12

5.0

Over 7/12 to 8/12

1.5*

 

Over 14/12 to 16/12

6.0

Over 8/12 to 9/12

2.0*

 

Over 16/12 to 18/12

7.0

Over 9/12 to 10/12

2.5

 

Over 18/12 to 20/12

7.5

Over 10/12 to 11/12

3.25

 

Over 20/12 to 21/12

8.0

 

* 3 ft. minimum in snow regions

 

 

*If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.

**In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap.

Figure 6.2 Multiple Termination Caps

Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening

22

Heatilator • Evolution • 4065-114 Rev. o • 11/11

Image 22
Contents Installation and Operation ModelsCongratulations Homeowner Reference InformationTable of Contents Finishing Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceControl Module Operation IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Lighting Instructions IPI Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Framing and Clearances Select Appliance LocationConstruct the Appliance Chase Clearances Clearances to CombustiblesMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsTop Vent Horizontal Termination Vent DiagramsOne Elbow Two 45 Elbows replacing One 90 Elbow Two ElbowsThree Elbows Top Vent Vertical TerminationNo Elbow Install Top Vent Flue Baffle No Elbow Configu- rations 7a Remove Flue Visor12 ft 3.66 m min 60 ft 18.29 m max 12 ft 3.66 m min ft 18.29 m max Rear Vent Horizontal Termination One 45 ElbowTwo Elbows Rear Vent Vertical Termination Min Ft 1.83 m max 12 ft 3.66 m min Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and atticsFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Top VentRear Vent It Cannot be changed at a later time BasketSecure and Level the Appliance 11 Proper Positioning and Securing of an ApplianceAssemble Vent Sections DVP Only Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe SectionsAssemble Vent Sections SLP Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap Failure to maintain overlap may cause overheating and fireField Constructed Shrouds ShroudsHHT Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHWMailbox Style Shroud Dimensions Min. Base Dims Gas Pressure Gas InformationFuel Conversion Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationElectrical Service and Repair WHTJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Marble/Granite Cut Dimensions Facing MaterialAppliance Setup Install the Glass Media Cleaning the Glass MediaPlace the Glass Media Replacing Fixed Glass Assembly Air Shutter SettingTroubleshooting Intellifire Ignition SystemGas supply Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP DVP-HRC-SS 168 mm SL-2DVP Description Part Number Service Parts NEVO3630i Stocked at DepotService Parts NEVO4236i Stocked Service Parts NEVO3630i, Nevo#13 Valve Assembly At DepotDescription Comments Part Number NEVO3630I Optional Components Catalog #Contact Information Do not Discard this Manual

NEVO4236I NEVO3630I specifications

Heatiator has made a significant mark in the world of modern heating solutions with its innovative NEVO4236I and NEVO3630I models. These versatile heating units are designed not just for efficiency but also to enhance the aesthetic appeal of any space.

The NEVO4236I and NEVO3630I both showcase sleek, contemporary designs that effortlessly blend into various interior styles. With a minimalist aesthetic, these units do not just serve as functional heaters; they also add a unique touch to the decor. The clean lines and attractive finish make them ideal for modern homes, offices, and commercial spaces.

One of the standout features of the Heatiator NEVO4236I and NEVO3630I is their advanced heating technology. Both models utilize electric heating elements that provide consistent and controlled warmth. This ensures a comfortable environment while maintaining energy efficiency. Users can enjoy rapid heat-up times, allowing spaces to reach optimal temperatures quickly without wasting energy.

In terms of user convenience, both models are equipped with smart technology features. They include programmable thermostats and remote control options, enabling users to easily adjust the temperature from anywhere in the room. This adds an extra layer of comfort and convenience, ensuring that spaces can be pre-warmed before occupants arrive.

Furthermore, safety is a critical aspect of the Heatiator NEVO4236I and NEVO3630I. Both units come with built-in safety features such as overheat protection and tip-over switches. These features provide peace of mind, particularly in homes with children or pets.

Another notable characteristic is their low noise operation. Unlike conventional heaters that can be noisy and disruptive, these models operate quietly, allowing for a tranquil environment perfect for relaxation or concentrated work.

The energy efficiency of the Heatiator NEVO4236I and NEVO3630I must not be overlooked. Designed to minimize electricity usage while maximizing heat output, they represent a sustainable choice for environmentally conscious consumers. This efficiency not only benefits the environment but also affects the energy bills positively.

In summary, the Heatiator NEVO4236I and NEVO3630I stand out for their modern design, advanced heating technologies, user-friendly features, safety measures, low noise levels, and energy efficiency. These attributes make them an excellent choice for anyone looking to enhance their heating solutions while maintaining aesthetics and functionality in their living or working spaces.