Weil-McLain GL-E223-ADOC 0311 manual Water heater maintenance, Monthly maintenance by user

Page 25

AQUA PLUS indirect-fired water heaters — Product Manual

Water heater maintenance

Boiler water — read and comply with all requirements under

Figure 21

T&P valve operation

“Boiler water restrictions,” page 3.

 

 

Water from opened drain valves, unions and other connec-

 

Before operating the T&P relief

tions may be extremely hot. To avoid severe personal injury,

 

 

valve, make sure no one is in front of

death or substantial property damage:

 

 

or around the T&P relief valve dis-

• Tighten all drain hose connections.

 

 

charge piping. Hot discharge water

• Direct hot water away from all persons.

 

 

can cause severe personal injury or

 

 

substantial property damage.

ATTENTION USER!

Have the water heater serviced at least once an- nually by a qualified service technician.

Follow the maintenance procedures below at least monthly.

Read “Water heater temperature adjustment,” page 24.

Failure to comply with the above can result in severe personal injury, death or substantial property dam- age.

MONTHLY maintenance by user

At least MONTHLY, visually check valves, pipes and fittings for leaks.

Check hot water supply at several outlets. Make sure water temperature is not too hot.

Call qualified service technician to repair leaks or address problems.

MONTHLY maintenance by user

At least MONTHLY, visually check valves, pipes and fittings for leaks.

Check hot water supply at several outlets. Make sure water temperature is not too hot.

Call qualified service technician to repair leaks or address problems.

ANNUAL start-up by qualified service technician

Obtain an Inspection and service kit (see“Replacement parts,” page 39) before attempting to perform the annual start-up. This kit contains items that will usually have to be replaced.

Check water supply temperature at several outlets to ensure the water temperature is acceptable for intended use and that all temperature control devices are functioning properly. Read page 3 and verify that all requirements are met by the installation.

Part number GL-E223-ADOC 0311

Plugging T&P relief valve or dis- charge piping can cause excessive pressure in the water heater, result- ing in severe personal injury, death or substantial property damage.

Perform the following procedures:

❏❏Perform any procedures required by local codes.

❏❏Verify system pressure both on domestic water and boiler water sides.

❏❏Manually operate T&P relief valve at least once a year (see Figure 21). This will release some hot water. Move operating lever to open position for a few seconds and then move it back, allowing it to snap closed. After T&P relief valve is operated, if it continues to release water, close cold water inlet to water heater immediately. Follow draining instructions, and replace the T&P relief valve. If T&P relief valve weeps periodically, it may be due to thermal expansion. Install an expansion tank if not already installed.

❏❏Follow instructions on circulator to oil it, if oil- lubricated.

❏❏Follow instructions in “Inspect anode and water heater interior,” page 26.

❏❏Check valves, pipes and fittings for leaks.

❏❏Check function of all controls and valves (see con- trol manufacturer’s instructions).

❏❏Review homeowner’s maintenance responsibilities

25

Image 25
Contents Product Manual Contents Please read before proceeding When servicing water heaterOperating restrictions Boiler water restrictionsRecommended clearances Pre-installationClearance to combustible materials Water heater operating restrictions Domestic water piping requirementsHot Water Can Scald Piping overview Domestic water pipingGeneral applications Massachusetts applicationsPipe from drain to floor drain, if available Recirculation Recirculation components Components Potential problemsOperation Boiler-side piping WiringZoning with circulators primary/secondary system piping Zoning with zone valves direct-connected system piping Zoning with zone valves primary/secondary system piping Dedicated single-boiler piping Multiple water heaters domestic water piping Cific details on installing Special considerations Connecting to a low-pressure steam boilerFilling the piping Boiler-side wiring and controls System piping Wiring zoning with circulatorsWiring zoning with zone valves Water heater filling and start-up Start-up checklistMaximum boiler-side flow rate Filling the domestic water tankSetting the thermostat Water heater temperature adjustmentGeneral notes Monthly maintenance by user Water heater maintenanceAnnual start-up by qualified service technician Perform the following proceduresDrain the water heater if necessary during shutdown periods Inspect anode and water heater interiorTroubleshooting procedures TroubleshootingPreparation for troubleshooting Insufficient hot water Water quality problemsTop of tank or insulation wet Undersized water heater? Insufficient hot waterBoiler system improperly sized? Check component parts Clean the boiler water system Check boiler operating temperaturesCheck location of flow control devices Check for air in the system check water heater air ventInstall a thermostatic mixing valve Excessive domestic water temperatureInstall a recirculation loop Reduce stackingFaulty boiler relief valve? Faulty boiler expansion tank?Faulty boiler fill valve? Boiler relief valve lifting or weepingTemperature/pressure relief valve lifting or weeping Top of tank or insulation wet Water on the floor near the tankCheck for leaks from sources other than the water heater Is the source of water from the T&P relief valve?Anodes last less than two years Rapid decay of magnesium anodeWater smells like rotten eggs Water quality problemsMilky water Discolored water from the hot water faucet Aqua Plus Replacement parts105 Ahri ratingsFirst Hour Rating Capacity GPH Boiler Water Supply at 200F Ratings with 200F boiler supply waterFirst Hour Rating Capacity GPH Boiler Water Supply at 190F Ratings with 190F boiler supply waterFirst Hour Rating Capacity GPH Boiler Water Supply at 180F Ratings with 180F boiler supply water105 Dimensions

GL-E223-ADOC 0311 specifications

The Weil-McLain GL-E223-ADOC 0311 is a notable addition to the lineup of high-efficiency cast iron boilers designed for both residential and commercial applications. This model stands out due to its focus on reliability, longevity, and energy efficiency, making it an ideal solution for those seeking effective heating solutions.

A key feature of the GL-E223 model is its durable cast iron construction. The cast iron heat exchanger not only enhances the boiler's overall resilience but also improves its thermal efficiency. This characteristic ensures the boiler can withstand the stress of continuous operation while providing consistent heating performance year after year.

The GL-E223-ADOC 0311 employs advanced burner technology, which optimizes combustion efficiency, reducing fuel consumption. With its ability to modulate based on the heating demand, the boiler adjusts its output to ensure it runs at peak efficiency, minimizing energy waste. This feature is particularly beneficial in terms of energy savings and reducing operational costs over time.

In terms of sizing, the Weil-McLain GL-E223 model is engineered to provide adequate heating for a wide range of applications. Its output capacity is meticulously designed to accommodate residential heating requirements while being robust enough for light commercial usage. The controls and monitoring systems integrated into this boiler allow for easy adjustments and improved system management.

One significant characteristic of this model is its built-in features for enhanced safety and convenience. The boiler includes safety controls that prevent overheating, as well as an easy-access inspection and cleaning configuration that extends the life of the unit and eases maintenance efforts.

Furthermore, the GL-E223-ADOC 0311 is designed to be compatible with a range of hydronic heating systems. This adaptability allows for seamless integration into existing infrastructure or new installations, allowing homeowners and businesses the potential for improved heating solutions without extensive modifications.

Overall, the Weil-McLain GL-E223-ADOC 0311 encompasses advanced engineering with its cast iron construction, efficient burner technology, and user-friendly features that ensure reliability and efficiency. Whether for new installations or upgrades, this boiler is a solid choice for efficient heating solutions, resonating well with those prioritizing energy conservation and long-term performance.