AQUA PLUS indirect-fired water heaters — Product Manual

Replacement parts

Figure 24 Water heater replacement parts

Item

Description

Size/Model

Weil-McLain

AQUA PLUS

Part Number

 

 

 

 

 

 

 

Magnesium anode replacement kit

35/45/55

633500014

 

 

 

1

(includes anode, o-ring, insulating

85

633500015

 

washer and brass bushing)

 

 

 

105

633500016

 

 

 

 

Aqua PLUS

 

 

 

Residential

633500020

2

Thermostat repair kit

(35/45/55)

 

Aqua PLUS

 

 

 

 

 

 

Commercial

633500021

 

 

(85/105)

 

 

 

35/45/55

633500024

3

Top plastic cap replacement kit

85

633500025

 

 

105

633500026

 

 

 

 

 

Bottom plastic cap replacement kit

35/45/55

633500030

 

 

 

4

85

633500031

(plastic cap and 4 screws)

 

 

 

 

105

633500032

 

 

5

Leveling leg replacement kit (4)

All

633500036

6

Temperature & pressure relief valve

35/45/55

633500038

kit

85/105

633500039

 

 

 

 

 

NS

Inspection and service kit (includes

All

633500042

inspection plate and anode seals)

 

 

 

7

Inspection plate replacement kit

All

633500044

8

Inspection hatch cover replacement

All

633500046

kit

 

 

 

9

Fitting grommet

¾”

633500064

1”

633500037

 

 

 

 

 

 

10

Anode cover

All

633500048

 

 

 

 

 

 

35, Pewter

633500049

 

 

 

 

 

 

45, Pewter

633500050

 

 

55, Pewter

633500051

 

 

85, Pewter

633500052

NS

Jacket replacement kit

105, Pewter

633500053

 

 

35, Gold

633500054

 

 

 

 

 

 

 

 

45, Gold

633500055

 

 

 

 

 

 

55, Gold

633500056

 

 

85, Gold

633500057

 

 

105, Gold

633500058

 

 

 

 

NS

Mixing valve kit, 1"

All

633500012

 

 

 

 

Part number GL-E223-ADOC 0311

39

Image 39
Contents Product Manual Contents Boiler water restrictions When servicing water heaterPlease read before proceeding Operating restrictionsPre-installation Recommended clearancesClearance to combustible materials Domestic water piping requirements Water heater operating restrictionsHot Water Can Scald Massachusetts applications Domestic water pipingPiping overview General applicationsPipe from drain to floor drain, if available Recirculation Recirculation components Potential problems ComponentsOperation Boiler-side piping WiringZoning with circulators primary/secondary system piping Zoning with zone valves direct-connected system piping Zoning with zone valves primary/secondary system piping Dedicated single-boiler piping Multiple water heaters domestic water piping Cific details on installing Special considerations Connecting to a low-pressure steam boilerFilling the piping Boiler-side wiring and controls System piping Wiring zoning with circulatorsWiring zoning with zone valves Filling the domestic water tank Start-up checklistWater heater filling and start-up Maximum boiler-side flow rateWater heater temperature adjustment Setting the thermostatGeneral notes Perform the following procedures Water heater maintenanceMonthly maintenance by user Annual start-up by qualified service technicianDrain the water heater if necessary during shutdown periods Inspect anode and water heater interiorTroubleshooting Troubleshooting proceduresPreparation for troubleshooting Water quality problems Insufficient hot waterTop of tank or insulation wet Insufficient hot water Undersized water heater?Boiler system improperly sized? Check component parts Check for air in the system check water heater air vent Check boiler operating temperaturesClean the boiler water system Check location of flow control devicesReduce stacking Excessive domestic water temperatureInstall a thermostatic mixing valve Install a recirculation loopBoiler relief valve lifting or weeping Faulty boiler expansion tank?Faulty boiler relief valve? Faulty boiler fill valve?Temperature/pressure relief valve lifting or weeping Is the source of water from the T&P relief valve? Water on the floor near the tankTop of tank or insulation wet Check for leaks from sources other than the water heaterAnodes last less than two years Rapid decay of magnesium anodeWater quality problems Water smells like rotten eggsMilky water Discolored water from the hot water faucet Aqua Plus Replacement parts105 Ahri ratingsFirst Hour Rating Capacity GPH Boiler Water Supply at 200F Ratings with 200F boiler supply waterFirst Hour Rating Capacity GPH Boiler Water Supply at 190F Ratings with 190F boiler supply waterFirst Hour Rating Capacity GPH Boiler Water Supply at 180F Ratings with 180F boiler supply water105 Dimensions

GL-E223-ADOC 0311 specifications

The Weil-McLain GL-E223-ADOC 0311 is a notable addition to the lineup of high-efficiency cast iron boilers designed for both residential and commercial applications. This model stands out due to its focus on reliability, longevity, and energy efficiency, making it an ideal solution for those seeking effective heating solutions.

A key feature of the GL-E223 model is its durable cast iron construction. The cast iron heat exchanger not only enhances the boiler's overall resilience but also improves its thermal efficiency. This characteristic ensures the boiler can withstand the stress of continuous operation while providing consistent heating performance year after year.

The GL-E223-ADOC 0311 employs advanced burner technology, which optimizes combustion efficiency, reducing fuel consumption. With its ability to modulate based on the heating demand, the boiler adjusts its output to ensure it runs at peak efficiency, minimizing energy waste. This feature is particularly beneficial in terms of energy savings and reducing operational costs over time.

In terms of sizing, the Weil-McLain GL-E223 model is engineered to provide adequate heating for a wide range of applications. Its output capacity is meticulously designed to accommodate residential heating requirements while being robust enough for light commercial usage. The controls and monitoring systems integrated into this boiler allow for easy adjustments and improved system management.

One significant characteristic of this model is its built-in features for enhanced safety and convenience. The boiler includes safety controls that prevent overheating, as well as an easy-access inspection and cleaning configuration that extends the life of the unit and eases maintenance efforts.

Furthermore, the GL-E223-ADOC 0311 is designed to be compatible with a range of hydronic heating systems. This adaptability allows for seamless integration into existing infrastructure or new installations, allowing homeowners and businesses the potential for improved heating solutions without extensive modifications.

Overall, the Weil-McLain GL-E223-ADOC 0311 encompasses advanced engineering with its cast iron construction, efficient burner technology, and user-friendly features that ensure reliability and efficiency. Whether for new installations or upgrades, this boiler is a solid choice for efficient heating solutions, resonating well with those prioritizing energy conservation and long-term performance.