Weil-McLain Radiant Heater manual Sleeper Layout Above Floor

Page 15

Above Floor Installation Guide

Figure 10 - Typical sleeper layout and installation

SLEEPER LAYOUT - ABOVE FLOOR

(Typical)

5

 

3

4

 

 

 

1

 

 

 

4

 

1

 

 

 

4

 

1

 

 

 

4

3

1

2

 

 

4

2

1

 

 

 

4

4

1

 

 

4

 

 

 

1

 

 

 

4

5

 

5

These drawings are conceptual only. Consult Weil-McLain Radiant Guides or Software for actual project layout.

1SLEEPERS

!Typically sleepers are 1 x __ lumber or ¾" CDX plywood . (Width of sleeper is equal to the required tube spacing less 1 inch.)

!Space 1" apart as shown to provide room for heat emission plate tubing channel and for thermal expansion.

!Begin at one side of the room. Place a 1 x 4 spacer (item 3) ¼" from wall as shown.

!Leave a 1" gap between spacer and first sleeper. Then glue and nail sleepers in place.

2END SUPPORT SLEEPERS

!Typically cut from 3/4" plywood. (Width of end sleepers should equal tube bend radius plus 4 inches.)

!Use a router and circle cutting template or fixture to route 3/4" wide x 5/8" deep channels as shown..

!Place the end supports about ¼" from the wall to allow room for expansion. Then glue and nail in place.

3SPACERS

!Typically 1 x 4 furring strips.

!Place spacers about ¼" from the wall to allow room for expansion. Then glue and nail in place.

!Use a spacer between the wall and one of the end support sleepers to provide a channel for the tubing to leave the room as shown.

4TUBING PATH

!Provide a 1" gap between spacer and end support sleeper for routing tubing out of room. This will allow placement of a heat emission plate along this route.

5PROVIDE GAP AROUND PERIMETER

!Provide ¼" gap around entire perimeter of room to allow for expansion.

Part Number 650-000-221/0298

15

Image 15
Contents AlumiPexÆ Codes and Standards Hazard DefinitionsAlumipex STEP-BY-STEP Above Floor Installation Heat Output from Radiant Floors Tube Layouts for Radiant HeatingRadiant Floor Heatng Radiant Floor Heating DesignAbove Floor Installation UT Y Floor Plan/Layout Should Obtain Tube Layout DrawingMeet with General Contractor AlumiPex Manifolds Obtain MaterialsAlumiPex Tubing AlumiPex Tube FittingsPressure Gauge Obtain Special EquipmentAlumiPex Reamer/Sizers Tubing UncoilerMark Floor Plan and Tube Layout on Subfloor Pre-Installation Check ListMount Manifolds Attach the manifold to a plywood panelPrepare holes for tube routing Manifold Mounting Install the Tubing Sleeper Layout Above Floor Above Floor Installation Pressure Test the Finished Tubing Installation Before Leaving the Jobsite Make a record of your installationConnect System Piping & Heating System Components Pressurize Tubing for ObservationInspection, Repair and Troubleshooting Inspect Tubing Before Finished Flooring InstallationAlumiPex Radiant Tubing

Radiant Heater specifications

Weil-McLain Radiant Heater is a standout choice for homeowners seeking efficient and reliable heating solutions. Renowned for its impressive energy efficiency and sleek design, it offers an array of features that cater to both comfort and performance.

One of the primary characteristics of Weil-McLain Radiant Heaters is their ability to provide consistent warmth. Utilizing radiant heat technology, these heaters warm up surfaces in a room, creating a cozy environment that feels comfortable from the moment you enter. Unlike traditional forced-air systems, radiant heating eliminates cold drafts, ensuring even heat distribution throughout the space.

A prominent feature is the use of high-quality materials in the construction of the heater. Weil-McLain employs durable, corrosion-resistant components that enhance the unit's longevity and reliability. This ensures that homeowners can enjoy consistent performance over many years, reducing the need for frequent repairs or replacements.

Weil-McLain offers a variety of sizes and configurations, making it easy for homeowners to find a model that fits their specific heating needs. Whether heating a small bathroom or a large living area, there is a radiant heater designed to excel in various applications. Additionally, many models come equipped with advanced thermostatic controls, allowing users to set and maintain their desired temperature easily.

Efficiency is a critical aspect of Weil-McLain Radiant Heaters. Designed to operate with minimal energy consumption, these heaters often exceed industry standards for efficiency, allowing homeowners to save on heating costs while enjoying optimal comfort. Many units are compatible with modern smart home technology, enabling remote monitoring and control for added convenience.

Furthermore, the aesthetic appeal of Weil-McLain Radiant Heaters cannot be overlooked. With their modern design and clean lines, they can seamlessly integrate into any home décor. Unlike bulkier heating systems, these heaters can be discreetly installed, enhancing the room's overall ambiance while providing the warmth needed during colder months.

In summary, the Weil-McLain Radiant Heater stands out for its ability to deliver comfortable, efficient heating. With durable construction, smart technology integration, and a variety of sizes, it meets the diverse needs of today's homeowners, ensuring warmth and comfort for years to come. That's what makes it a top choice in the world of home heating solutions.