Weil-McLain Radiant Heater manual Ut Y

Page 6

AlumiPex Radiant Tubing

TUBELAYOUTDRAWINGFigure-6 -TypicalTypical tube layout drawing

washer / dryer

 

KITCHEN

 

DK

U

B

T

A

DINING

I

T

L

H

 

 

I

 

 

T

BT

 

UT Y

 

 

MANIFOLD

 

LIVING ROOM

 

LR1

LR2

BEDROOM

 

 

BR1

Slab Control Joint

BEDROOM

BR3

BEDROOM

BR2

 

This drawing is conceptual only. Consult Weil-McLain Radiant Guides or Software for actual project layout.

 

 

Tube Spacing

Circuit

 

Leader

 

Length

Total

Tubing

Finished

(Center to Center)

 

 

Tube

Length

 

Length

 

Allowance

Circuit

Flooring

 

 

 

 

 

Length

 

 

 

 

 

 

 

 

Normal

 

Close

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inches

 

Inches

Feet

 

Feet

 

Feet

Feet

LR1

Low pile carpet w/ thermal pad

8.5

 

 

178

 

43

 

10

231

LR2

Low pile carpet w/ thermal pad

8.5

 

6.5

192

 

22

 

10

224

DK

Laminated hardwood

12.5

 

6.5

227

 

28

 

10

265

UT

Ceramic tile

6.5

 

 

45

 

4

 

10

59

 

 

 

 

 

 

 

 

 

 

 

BT

Ceramic tile

6.5

 

 

79

 

12

 

10

101

 

 

 

 

 

 

 

 

 

 

 

BR1

Laminated hardwood

8.5

 

6.5

141

 

22

 

10

173

 

 

 

 

 

 

 

 

 

 

 

BR2

Laminated hardwood

8.5

 

6.5

163

 

22

 

10

195

 

 

 

 

 

 

 

 

 

 

 

BR3

Laminated hardwood

8.5

 

6.5

156

 

19

 

10

185

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil

Coil Length

Tube Size

 

 

Use for Circuits Listed

Total

Number

 

 

Length

 

 

 

 

 

 

 

 

 

1

1000 feet

1/2"

 

 

LR1, LR2, DK, UT & BR2

974

 

 

 

 

 

 

 

 

 

2

300 feet

1/2"

 

 

BT & BR3

 

 

286

 

 

 

 

 

 

 

 

 

 

3

300 feet

1/2"

 

 

 

BR1

 

 

173

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

Part Number 650-000-221/0298

Image 6
Contents AlumiPexÆ Hazard Definitions Codes and StandardsAlumipex STEP-BY-STEP Above Floor Installation Radiant Floor Heating Design Tube Layouts for Radiant HeatingRadiant Floor Heatng Heat Output from Radiant FloorsAbove Floor Installation UT Y Obtain Tube Layout Drawing Floor Plan/Layout ShouldMeet with General Contractor AlumiPex Tube Fittings Obtain MaterialsAlumiPex Tubing AlumiPex ManifoldsTubing Uncoiler Obtain Special EquipmentAlumiPex Reamer/Sizers Pressure GaugePre-Installation Check List Mark Floor Plan and Tube Layout on SubfloorMount Manifolds Attach the manifold to a plywood panelPrepare holes for tube routing Manifold Mounting Install the Tubing Sleeper Layout Above Floor Above Floor Installation Pressure Test the Finished Tubing Installation Pressurize Tubing for Observation Make a record of your installationConnect System Piping & Heating System Components Before Leaving the JobsiteInspect Tubing Before Finished Flooring Installation Inspection, Repair and TroubleshootingAlumiPex Radiant Tubing

Radiant Heater specifications

Weil-McLain Radiant Heater is a standout choice for homeowners seeking efficient and reliable heating solutions. Renowned for its impressive energy efficiency and sleek design, it offers an array of features that cater to both comfort and performance.

One of the primary characteristics of Weil-McLain Radiant Heaters is their ability to provide consistent warmth. Utilizing radiant heat technology, these heaters warm up surfaces in a room, creating a cozy environment that feels comfortable from the moment you enter. Unlike traditional forced-air systems, radiant heating eliminates cold drafts, ensuring even heat distribution throughout the space.

A prominent feature is the use of high-quality materials in the construction of the heater. Weil-McLain employs durable, corrosion-resistant components that enhance the unit's longevity and reliability. This ensures that homeowners can enjoy consistent performance over many years, reducing the need for frequent repairs or replacements.

Weil-McLain offers a variety of sizes and configurations, making it easy for homeowners to find a model that fits their specific heating needs. Whether heating a small bathroom or a large living area, there is a radiant heater designed to excel in various applications. Additionally, many models come equipped with advanced thermostatic controls, allowing users to set and maintain their desired temperature easily.

Efficiency is a critical aspect of Weil-McLain Radiant Heaters. Designed to operate with minimal energy consumption, these heaters often exceed industry standards for efficiency, allowing homeowners to save on heating costs while enjoying optimal comfort. Many units are compatible with modern smart home technology, enabling remote monitoring and control for added convenience.

Furthermore, the aesthetic appeal of Weil-McLain Radiant Heaters cannot be overlooked. With their modern design and clean lines, they can seamlessly integrate into any home décor. Unlike bulkier heating systems, these heaters can be discreetly installed, enhancing the room's overall ambiance while providing the warmth needed during colder months.

In summary, the Weil-McLain Radiant Heater stands out for its ability to deliver comfortable, efficient heating. With durable construction, smart technology integration, and a variety of sizes, it meets the diverse needs of today's homeowners, ensuring warmth and comfort for years to come. That's what makes it a top choice in the world of home heating solutions.