Weil-McLain UO-3 CV, UO-5 CV manual General Information To the Owner, Burner Specif cations, Weekly

Page 5

General Information

To the Owner:

Thank you for purchasing a Beckett burner

for use with your heating appliance. Please pay at- tention to the Safety Warnings contained within this instruction manual. Keep this manual for your records and provide it to your qualified service agency for use in professionally setting up and maintaining your oil burner.

Your Beckett burner will provide years of efficient op- eration if it is professionally installed and maintained by a qualified service technician. If at any time the burner does not appear to be operating properly, im- mediately contact your quali f ed service agency for consultation.

We recommend annual inspection/service of your oil heating system by a qualif ed service agency.

Daily – Check the room in which your burner/appli- ance is installed. Make sure:

Air ventilation openings are clean and unobstruct- ed

Nothing is blocking burner inlet air openings

No combustible materials are stored near the heat- ing appliance

There are no signs of oil or water leaking around the burner or appliance

Weekly

Check your oil tank level. Always keep your oil tank full, especially during the summer, in order to pre- vent condensation of moisture on the inside surface of the tank.

!WARNING Do NOT Alter the Original Burner Design

Tampering with or altering the burner design could seriously impair performance, resulting in loss of static pressure, damage to the system components, reduced air volume, heavy smoke, flame impingement, appliance sooting, hot gas puff-back, and asphyxiation or fire hazards.

Maintain the design to its original configuration. Only use parts specified for AF or AFG Burners

Do NOT remove the air guide from the AFG chassis.

Do NOT use ‘M’ Series air tube combinations on AF Burn- ers.

Never try to convert an AF to an AFG or vice versa Any design alteration will:

yVoid UL Listing

yVoid manufacturer’s warranties

ySeriously impact burner performance

yGreatly increase your liability risk

Page 4

!WARNING Impaired Burner Perfor- mance and Fire Hazard.

Do NOT operate the burner beyond specif ca- tions outlined in the following Table.

yFor applications beyond these limits, consult Beckett Technical Service at 1-800-645-2876.

yNOTE: Some packaged appliances with burners may be agency listed as a unit to operate beyond these limits. Consult the appliance manufac- turer’s specifications and agency approvals for verification.

Table 1 – Burner Specif cations

Capacity

‘F’ Head (AF & AFG)

(Note 1)

Firing rate range:

..............0.40 – 3.00 GPH

 

Input: ....................... 56,000 – 420,000 Btu

 

 

 

 

 

‘L1’ Head (AFG Only)

 

Firing rate range: ..................0.40 - 1.10 GPH

 

Input: ..................... 56,000 – 154,000 Btu/h

 

‘L2’ Head (AFG Only)

 

Firing rate range: .................0.50 - 1.00 GPH

 

Input: ...................... 70,000 – 140,000 Btu/h

 

‘V1’ Head (AFG Only)

 

Firing rate range: .................0.75 - 2.75 GPH

 

Input: .................... 105,000 – 385,000 Btu/h

Certifications/

UL listed to comply with ANSI/UL296 and CSA-B140.0

Approvals

 

 

 

 

Fuels

U. S No. 1 or No. 2 heating oil only (ASTM D396)

 

Canada No. 1 stove oil or No. 2 furnace oil only

 

 

 

 

 

 

! CAUTION

 

 

DO NOT USE GASOLINE, CRANKCASE OIL,

 

OR ANY OIL CONTAINING GASOLINE.

 

 

 

 

 

Electrical

Power supply:............ 120 volts AC, 60 Hz single phase

 

Operating load: .......... Amps max

 

Motor: .........................1/7 hp, 3450 rpm, NEMA 48M frame

 

 

 

PSC rotation CCW when facing

 

 

 

shaft end

 

Ignition: ......................Continuous duty solid-state igniter

Fuel pump

Outlet pressure: ..................................Note 2

 

 

 

 

 

Air tube

ATC code:

See Table 2

 

 

 

 

 

Dimensions

Height (maximum)

12.5 inches

(with cover)

Width (maximum) .......................... 15 inches

 

Depth ......................................... 9.25 inches

 

Air tube diameter ....................... 4.00 inches

Ambient

+32o F. (0 C.) Minimum

Operating

+115o F. (+46 C.) Maximum

Temperature

(See above Warning)

Moisture

5% to 95% RH, non-condensing and non-crystallizing

 

 

 

 

 

Note 1: Approval agency listed rating for these burners is 0.40 to 3.00 gph. However, the firing rate range is limited by the specific air tube combination being used. Refer to Table 2.

Note 2. See appliance manufacturer’s burner specifications for rec- ommended pump discharge pressure.

6104BAFG R06

Image 5
Contents R02 01/09 To the Homeowner or Equipment Owner To the Professional, Qualif ed Installer or Service AgencyPotential for Fire, Smoke and Asphyxiation Hazards Information To Be Used Only By Qualif ed Service Technicians Table of ContentsHazard Definitions FeatureGeneral Information Indicates a hazardous situWeekly General Information To the OwnerBurner Specif cations Air Tube Combination ATC codes General SpecificationsInspect Chimney or Direct Vent System Tion Hazard Inspect/Prepare Installation SiteClearances to burner and appliance Chamber DimensionsCombustion chamber Burner retrof t- ting NozzleInspect/Prepare Installation Site Prepare the Burner Mount burner on appliance Prepare the BurnerBurner Dimensions Check/Adjust ‘Z’ Dimension ‘F’ headsCheck/Adjust ‘Z’ Dimension L1 & L2 Heads Fuel Line Valves and Filter Installing the Oil Tank and Supply SystemBurner installed at jobsite Wire burnerSpecial wiring required with covered burners Frozen Plumbing Water Damage HazardFeatures WiringBurner Controls GeniSys Model 7505 Control Fire or Explosion HazardBurner Controls Light Color On Continuously Flashing Reset Button OperationControl System Features Typical Burner WiringResetting From Restricted or Hard Lockout Cad Cell Resistance IndicatorStart up burner/set combustion Hot Gas Puff-Back Heavy Smoke HazardStartup / Checkout Check Safety FeaturesStartup/Checkout Set combustion with instrumentsShutting the Burner Off Perform regular maintenanceReplace the blower wheel Blower wheel assemblyPage Description Warranty

UO-3 CV, UO-4 CV, UO-5 CV specifications

Weil-McLain is a well-respected name in the heating industry, recognized for its high-quality and efficient boiler systems. Among its notable offerings are the UO-3 CV, UO-4 CV, and UO-5 CV models, all of which showcase advanced engineering and innovative technology tailored for residential and commercial applications.

The UO-3 CV boiler is designed for mid-sized heating requirements, boasting a strong output capacity that balances efficiency with performance. It features a compact size, suitable for smaller installations, without sacrificing power. The boiler is equipped with a durable cast iron heat exchanger that provides excellent thermal efficiency and longevity, ensuring reliable operation over the years. Its easy access for maintenance also makes it a popular choice among HVAC professionals.

Moving to the UO-4 CV model, this boiler builds on the success of the UO-3 with an increased output capacity, making it ideal for larger residential or light commercial spaces. The UO-4 CV incorporates Weil-McLain’s advanced combustion technology, which optimizes fuel use and significantly reduces emissions. This model maintains a compact design while enhancing overall performance through improved heat transfer and reduced standby losses. The UO-4 CV's user-friendly features, including easy-to-use controls and a diagnostic system, streamline operational efficiency.

The UO-5 CV further solidifies Weil-McLain's commitment to excellence with its highest output among the three. This boiler is particularly suited for extensive heating demands, making it popular among larger commercial installations. The UO-5 CV also employs cutting-edge technology, including advanced controls for precise temperature regulation and an efficient system designed to minimize energy consumption. Its robust construction ensures it can handle heavy use while remaining reliable, even in challenging environments.

In summary, the Weil-McLain UO series, including the UO-3 CV, UO-4 CV, and UO-5 CV, represents a perfect blend of efficiency, innovation, and reliability. All models utilize durable materials, advanced engineering, and state-of-the-art technologies that define Weil-McLain's reputation for quality in hydronic heating solutions. Whether for residential or commercial applications, these boilers serve as dependable sources of heat, catering to various needs while maintaining energy efficiency and lower emissions.