TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching from Manual to Auto mode wait 1 1/2 minutes.
❒Turn the SENSITIVITY (SENS) control to the mid position and the
The detector is less sensitive to motion directly towards it and more sensitive to cross motion.
Motion | Motion |
| Sensor |
Least Sensitive | Most Sensitive |
SENS | |
| |
10 5 1 TEST | MIN MAX |
Bottom of Sensor
Avoid aiming the control at:
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.
❒Adjust the SENSITIVITY as needed. Too much sensitivity may increase false triggering.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
5 to 9' | 110° |
| |
| |
60 ft. |
|
(18m) |
|
Maximum Range | Maximum |
| Coverage Angle |
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60' (18m) [varies with surrounding temperature].
Sensing Angle . . . . . . . Up to 110°
Electrical Load. . . . . . . Up to 150Watts Maximum (per adapter) Incandescent.
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL Time Delay . . . . . . . . . 1 , 5, 10 minutes Sensitivity . . . . . . . . . . Adjustable
DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
3 |