INSTALLATION
Estimated Installation Time: 30 minutes Items needed for installation (not included):
• | Phillips and flathead screwdrivers | |
• | Pliers | • Wire strippers/cutters |
• | Safety glasses | • Silicone caulk |
• | Ladder | • Black tape |
WARNING: Turn power off at circuit breaker or fuse.
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.
For eave mount only:
❒Swing the sensor head towards the clamp screw joint.
Controls
Clamp Screw
❒Then rotate the sensor head clockwise 180° so the controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
Wire the Light Control
These instructions show the sensor wired to floodlamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the switched “hot” wire. The lighting load (500Watts, 4.2 A max.incandescent only) is placed across the white and red wires.
❒Remove the existing light fixture, if present.
❒After screwing the sensor into the wall plate, connect the junction box wires to the light control wires by twisting together and securing with wire connectors.
2.RED CONTROL WIRE & BLACK FIXTURE WIRES
1.ALL WHITE WIRES
Junction Box
Bulb Holders
3. BLACK |
|
| |
CONTROL |
|
| |
WIRE & BLACK |
|
| |
Optional: Connect additional load | |||
JUNCTION BOX |
| ||
| across the white and red wires. Total | ||
WIRE |
| ||
| lighting load including bulb holders on | ||
|
| ||
|
| ||
|
| fixture must not exceed 500W (4.2A). | |
|
|
|
Mount the Light
❒Follow the instructions that came with your light fixture for mounting and adjusting the light fixture.
❒Keep regular