Heath Zenith manual Operation, Operating Instructions & Parts Manual 2LBN3, 2LBN4, Features

Page 1

Operating Instructions & Parts Manual

2LBN3, 2LBN4

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or main- tain the product described. Protect yourself and others by observing all safety information. Failure to comply could result in personal injury and/or property damage! Save these instructions for future reference.

®

DualBrite® Replacement Sensor Head

TEST

Put ON-TIME switch ON-TIME

DualBrite®

on the sensor bottom

 

 

 

 

 

 

 

 

 

 

 

 

to TEST and the Dual-

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

Off 3 6 Dusk to

Brite® switch OFF.

 

 

 

 

Dawn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5,

 

 

ON-TIME

or 20 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

 

 

 

 

 

 

 

 

 

MANUAL MODE

 

 

 

 

 

 

 

 

Features

• DualZone™ Technology.

Turns on lighting when motion is detected.

Automatically turns lighting off.

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.

1 Second OFF

then...

Patented DualBrite® Timer.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

... back on.

Mode Switching Summary

Requirements

Not for use with fluorescent lights.

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Install sensor in accordance with local codes.

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 20 Min

 

x

Manual

To Dawn*

 

x

Accent

3, 6 Hr, to Dawn

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

 

TEST

 

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1, 5, or 20 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.

DualBrite® TIMER

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.

HEA 011

598-1115-04

Printed in China

LPG-5316

09/07

 

Image 1
Contents Mode Switching Summary Requirements FeaturesDualBrite Timer OperationBlack InstallationSpecifications Test and AdjustmentMaximum Range Least Sensitive Most SensitiveYear limited warranty Troubleshooting GuideSymptom Possible Cause Manual de Instrucciones y Partes 2LBN3, 2LBN4 FuncionamientoCaracterísticas RequisitosLUZ DE DOS Niveles DualBrite InstalacionAdvertencia Desconecte la energía en el disyuntor BlancosEspecificaciones Prueba Y AjusteAngulo de Alcance Máximo Cobertura MáximaGarantía limitada a un 1 año Guia DE Investigacion DE AveriasRésumé du mode de commutation Mode d’emploi et guide des pièces 2LBN3, 2LBN4Fonctionnement CaractéristiquesMinuterie DualBriteMD Montage De La Commande D’ÉclairageNoir Le moins sensible Le plus sensible Essais ET RéglagesPortée maximale Angle de couverture Éviter de pointer l’appareilGuide DE Dépannage Fiche TechniqueGarantie limitée d’un an