Heath Zenith 2LBN3 manual Test and Adjustment, Specifications, Maximum Range

Page 3
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the RANGE control to the medium position (halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position.

MAX

 

ON-TIME

DUAL BRITE™

 

O

 

B

 

 

 

O

 

 

 

S

 

 

 

T

 

 

MIN

TEST 1 5 20

OFF 3 6 DUSK TO

RANGE

 

MINUTES

HOUR DAWN

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

240°

15 ft.

DualZone

(4.6 m)

 

 

DualZone

70 ft. 100 ft.

 

(21 m) (30.5 m)

 

 

Boosted

 

 

 

Maximum

Maximum Range

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

MotionMotion

Loosen the clamp screw

Clamp

in the sensor ball joint and

Screw

gently rotate the sensor.

 

Walk through the coverage

Ball

area noting where you are

Joint

when the lights turn on (also,

 

the LED will flash several

 

times when motion is detect-

 

ed).Move the sensor head up,

 

down, or sideways to change

Aim Sensor

the coverage area. Keep the

Down for Short

sensor at least 1" (2.5 cm)

Coverage

away from the bulbs.

 

AdjusttheRANGEasneeded.

RANGE set too high may increase false triggering.

Secure the sensor head's aim by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).

Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

NOTE: DualZone™ adds a zone of detection under the motion sensor. DualZone™ requires no additional adjustment and operates in conjuction with the for- ward-looking sensor.

SPECIFICATIONS

Horizontal Range. .

. Up to 70 ft. (21 m); 100 ft.

 

(30.5 m) with Range Boost.

 

[varies with surrounding

 

temperature]

Vertical Range. . .

. Up to 15 ft. (4.6 m)

Sensing Angle. . .

. Up to 240° horizontal. Up to 80°

 

Vertical

Electrical Load. . .

. Up to 500 Watts Maximum In-

 

candescent

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

 

MODE

Time Delay . . . .

. 1, 5, 20 minutes

DualBrite® Timer. .

. Off, 3, 6 hours, Dusk-to-Dawn

DualZone

Sensor

DualZone

 

 

Least Sensitive

 

Most Sensitive

598-1115-04

Image 3
Contents Operation FeaturesMode Switching Summary Requirements DualBrite TimerBlack InstallationLeast Sensitive Most Sensitive Test and AdjustmentSpecifications Maximum RangeTroubleshooting Guide Year limited warrantySymptom Possible Cause Requisitos FuncionamientoManual de Instrucciones y Partes 2LBN3, 2LBN4 CaracterísticasBlancos InstalacionLUZ DE DOS Niveles DualBrite Advertencia Desconecte la energía en el disyuntorAlcance Máximo Cobertura Máxima Prueba Y AjusteEspecificaciones Angulo deGarantía limitada a un 1 año Guia DE Investigacion DE AveriasCaractéristiques Mode d’emploi et guide des pièces 2LBN3, 2LBN4Résumé du mode de commutation FonctionnementMontage De La Commande D’Éclairage Minuterie DualBriteMDNoir Éviter de pointer l’appareil Essais ET RéglagesLe moins sensible Le plus sensible Portée maximale Angle de couvertureFiche Technique Guide DE DépannageGarantie limitée d’un an