TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.
❒Turn the RANGE control to the medium position (halfway between MIN and MAX), DualBrite® to OFF, and the
MAX |
| DUAL BRITE™ | ||
| O | |||
| B |
|
| |
| O |
|
| |
| S |
|
| |
| T |
|
| |
MIN | TEST 1 5 20 | OFF 3 6 DUSK TO | ||
RANGE | ||||
| MINUTES | HOUR DAWN |
Bottom of Sensor
Avoid aiming the sensor at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
240°
15 ft. | DualZone™ | ||
(4.6 m) | |||
|
| ||
DualZone™ | 70 ft. 100 ft. |
| |
(21 m) (30.5 m) |
| ||
| Boosted |
| |
|
| Maximum | |
Maximum Range | Coverage Angle |
NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
MotionMotion
❒ Loosen the clamp screw | Clamp | |
in the sensor ball joint and | Screw | |
gently rotate the sensor. |
| |
❒ Walk through the coverage | Ball | |
area noting where you are | ||
Joint | ||
when the lights turn on (also, | ||
| ||
the LED will flash several |
| |
times when motion is detect- |
| |
ed).Move the sensor head up, |
| |
down, or sideways to change | Aim Sensor | |
the coverage area. Keep the | ||
Down for Short | ||
sensor at least 1" (2.5 cm) | ||
Coverage | ||
away from the bulbs. | ||
|
❒AdjusttheRANGEasneeded.
RANGE set too high may increase false triggering.
❒ Secure the sensor head's aim by tightening the clamp screw. Do not overtighten the screw.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).
❒Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs.,
NOTE: DualZone™ adds a zone of detection under the motion sensor. DualZone™ requires no additional adjustment and operates in conjuction with the for-
SPECIFICATIONS
Horizontal Range. . | . Up to 70 ft. (21 m); 100 ft. |
| (30.5 m) with Range Boost. |
| [varies with surrounding |
| temperature] |
Vertical Range. . . | . Up to 15 ft. (4.6 m) |
Sensing Angle. . . | . Up to 240° horizontal. Up to 80° |
| Vertical |
Electrical Load. . . | . Up to 500 Watts Maximum In- |
| candescent |
Power Requirements. 120 VAC, 60 Hz | |
Operating Modes. . . TEST, AUTO and MANUAL | |
| MODE |
Time Delay . . . . | . 1, 5, 20 minutes |
DualBrite® Timer. . | . Off, 3, 6 hours, |
DualZone™ | Sensor | DualZone™ |
|
| |
Least Sensitive |
| Most Sensitive |