Dayton Operating Instructions and Parts Manual | 3E358B and 3E359B |
Dayton® Portable
Maintenance (Continued)
FOR HEATERS WITH FUEL FILTER INTERNAL TO PUMP
1.Remove pump cover to access filter.
2.Rinse and wipe inside of pump cover and dry with clean cloth.
3.Rinse fuel filter in clean kerosene or blow compressed air from inside out.
4.Reassemble and tighten securely. Check for leaks.
Pump Fuel
Cover Filter
6.Rinse fuel filter in clean Kerosene.
7.Put clean fuel filter and gasket back in canister bottom.
8.Screw canister bottom into canister top.
9.Tighten securely. Check for leaks.
Canister
Top
Gasket
Fuel Filter
Canister
Bottom
PUMP
(Procedure if pump is binding)
1.Remove upper shell (See Figure 8, page 7).
2.Loosen hex screw on flange clamp at rear of motor with 5/16"
3.Turn fan with hand (See Figure 16).
4.If fan turns freely, tighten screw on flange clamp.
5.If fan does not turn freely, replace pump.
6.Replace upper shell.
Hex Screw On
Flange Clamp
Figure 14 - Fuel Pump Filter and Canister
Figure 13 - Fuel Pump and Filter
FOR HEATERS WITH FUEL FILTER/ CANISTER EXTERNAL TO PUMP
1.Unscrew canister bottom from canister top with Channellock pliers.
2.Remove fuel filter and gasket from canister bottom (See Figure 14).
3.Inspect canister bottom and fuel filter for water or dirt.
4.Rinse canister bottom in clean Kerosene.
5.Wipe inside of canister bottom dry with clean cloth.
Figure 15 - Location of Screw on Flange Clamp
Figure 16 - Turning Fan with Hand
8