Dayton 3E358B, 3E359B specifications Fuel Lines, Nozzle

Page 9

Dayton Operating Instructions and Parts Manual

Models 3E358B and 3E359B

Maintenance (Continued)

FUEL LINES

(Procedure for tightening fuel lines)

1.Remove upper shell (See Figure 8, page 7).

2.Use 7/16" wrench and tighten fuel lines at solenoid valve, pump, and fuel filter canister (if equipped) (See Figure 17).

Fuel Pump/ Filter

8.Inspect nozzle for damage. If damaged or clogged, replace nozzle.

9.Make sure plug is in place on burner head.

10.Replace nozzle into burner head and tighten firmly (175-200 inch- pounds).

11.Attach burner head to combustion chamber.

12.Install spark plug in burner head.

Burner Head

Solenoid

Valve

Fuel

Line

Figure 17 - Fuel Line at Solenoid Valve

13. Attach spark plug wire to spark plug.

14. Attach fuel line to solenoid valve. Tighten firmly.

Fuel 15. Replace upper shell.

Lines

Figure 18 - Fuel Lines at Pump and

Nozzle

 

Plug

Spark Plug

Pump/Filter Assembly

 

 

NOZZLE

 

 

1.

Remove upper shell (See Figure 8,

 

 

 

page 7).

 

Spark Plug

2.

Remove fuel line from solenoid

 

Wire

Burner

Solenoid Valve

 

valve using 7/16" wrench.

 

 

Head

Fuel Line

 

 

3.

Remove spark plug wire from spark

 

 

 

 

plug.

Figure 19 - Replacing Nozzle

4.Remove spark plug from burner head using 13/16" open-end wrench.

5.Remove five screws using 5/16" nut- driver and remove burner head from combustion chamber.

6.Place burner head into vise and lightly tighten.

7.Carefully remove nozzle from burner head using 5/8" socket wrench (See Figure 19).

®

9

Image 9
Contents General Specifications DescriptionUnpacking Product Identification Dayton Portable Oil-Fired HeatersModels 3E358B and 3E359B General Safety InformationGeneral Safety Information Fuels OperationVentilation Fresh AIR Opening RequirementsTo Restart Heater To Stop HeaterFuel Filters MaintenanceUpper Shell Removal FAN Blades and AIR DeflectorsPump For Heaters with Fuel Filter Internal to PumpNozzle Fuel LinesAdjusting Pump Pressure Maintenance KitsStoring, Transporting, or Shipping Preventative Maintenance ScheduleSee Storing, Transporting, or Shipping See Fan Blades and Air Deflectors,Wiring Diagram Wiring DiagramSee Fan Blades and Air Deflectors Troubleshooting ChartHigh Voltage Transporting, or Shipping ,Storing, Transporting, or Shipping For Repair Parts, call Repair Parts List Repair Parts Illustration for Burner Head Assembly Accessory Figure Burner Head Assembly Figure3E358B Reference Number Description Part Number Quantity 3E359B WLI-1C Not a UPC