Dayton 2E511E, 3E219D, 2E510E Storing Transporting, or Shipping, Preventative Maintenance Schedule

Page 11

Dayton Operating Instructions and Parts Manual

Models 2E510E, 2E511E, 3E218E, and 3E219D

Storing Transporting, or Shipping

NOTE: If shipping, transport companies require fuel tanks to be empty.

1. Drain fuel tank.

NOTE: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed.

2.Replace drain plug if provided.

3.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use.

4.Replace fuel cap or drain plug. Prop- erly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.

5.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over summer months for use during next heat- ing season. Using old fuel could damage heater.

Preventative Maintenance Schedule

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

Item

How Often

How To

Fuel tank

Flush every 150-200 hours of operation or as needed

See Storing, Transporting, or Shipping,

 

 

above

Air output and

Replace every 500 hours of operation or once a year

See Air Output, Air Intake, and Lint

lint filters

 

Filters, page 6

Air intake filter

Wash and dry with soap and water every 500 hours of

See Air Output, Air Intake, and Lint

 

operation or as needed

Filters, page 6

Fuel filter

Clean twice a heating season or as needed

See Fuel Filter, page 7

Fan blades

Clean every season or as needed

See Fan, page 6

Motor

Not required/permanently lubricated

 

®

104447

11

Image 11
Contents Unpacking SpecificationsGeneral Specifications DescriptionProduct Identification Electrical SpecificationsModels 2E510E, 2E511E, 3E218E, and 3E219D General Safety InformationGeneral Safety Information Theory of Operation Fuels Operation AssemblyVentilation AIR OUTPUT, AIR INTAKE, and Lint Filters MaintenanceUpper Shell Removal FANFuel Filter Pump Pressure AdjustmentRemove ignitor screw with a 1/4 IgnitorNozzle Fuel and AIR Line Replacement and Proper RoutingPump Rotor Ignition Control AssemblyStoring Transporting, or Shipping Preventative Maintenance ScheduleMotor and Pump Assembly for Models 2E510E and 2E511E For Replacement Parts, Call Hours a Day 365 Days a YearPart 2E510E 2E511E Description Number Qty Burner Head Assembly for All Models Figure2E510E and 2E511E Models 2E510E and 2E511E Portable Oil-Fired Heaters Replacement Parts List for Models 2E510E and 2E511E3E218E Model 3E218E Replacement Parts List for Model 3E218E3E219D Model 3E219D Replacement Parts List for Model 3E219DAccessories Maintenance KitsIgnition Control Wiring DiagramSee Ignition Control Assembly, Troubleshooting ChartSymptom Possible Causes Corrective Action 2E510E, 2E511E, 3E218E, and 3E219D Limited Warranty

2E511E, 2E510E, 3E219D specifications

The Dayton 3E219D, 2E511E, and 2E510E are air circulators that embody modern advancements in design and technology, offering exceptional performance and efficiency. Each model brings unique features, making them suitable for various applications, be it in residential, commercial, or industrial settings.

The Dayton 3E219D stands out for its powerful motor that delivers high air movement while maintaining quiet operation. It is equipped with a 3-speed motor, allowing users to select the desired airflow according to their preferences and environmental conditions. The durable construction ensures longevity, with a corrosion-resistant finish ideal for various environments. One of its notable characteristics is the ability to tilt, allowing targeted airflow to specific areas, enhancing comfort significantly.

In contrast, the Dayton 2E511E provides enhanced portability and versatility. With a lightweight design and built-in handle, it can easily be moved from one location to another. This unit also features a three-speed switch, which allows users to adjust airflow as needed. Additionally, the 2E511E is designed to be energy-efficient, making it an environmentally friendly choice that helps reduce electricity bills without compromising performance. Its compact size makes it an excellent choice for tight spaces, while still delivering powerful air circulation.

Meanwhile, the Dayton 2E510E is engineered for heavy-duty usage. This model is built to withstand rigorous operational demands, making it an ideal choice for industrial applications. The sturdy metal housing and protective grille enhance safety and durability even in challenging conditions. Similar to its counterparts, it features a three-speed setting, providing flexibility in airflow management. Furthermore, the 2E510E is designed to promote effective air circulation across larger areas, making it suitable for warehouses or manufacturing facilities.

Together, these three models exemplify Dayton's commitment to quality and performance. Whether you need a robust air circulator for an industrial setting, a portable solution for home use, or a versatile unit for medium applications, Dayton has addressed diverse consumer needs. The integration of energy-efficient designs, user-friendly features, and durable construction ensures that each model provides reliable and long-lasting performance, catering to various airflow requirements. With Dayton's offerings, users can enjoy enhanced comfort and improved air quality in any environment.