Dayton 2E510E, 3E219D, 2E511E specifications General Safety Information Theory of Operation Fuels

Page 4

Dayton Operating Instructions and Parts Manual

2E510E, 2E511E, 3E218E, and 3E219D

Dayton® Portable

Oil-Fired Heaters

General Safety Information

Theory of Operation

Fuels

 

(Continued)

 

THE FUEL SYSTEM

 

 

 

Use only Kerosene

 

 

 

 

 

 

 

 

 

 

Heaters used in the vicinity of

The air pump forces air through the

 

 

 

or No. 1 fuel oil to

 

 

 

avoid risk of fire or explosion. Never

 

tarpaulins, canvas, or similar

air line. The air is then pushed

 

use gasoline, naphtha, paint thinners,

 

enclosure materials shall be located

through the burner head nozzle. This

alcohol, or other highly flammable

 

a safe distance from such materials.

air causes fuel to lift from the tank. A

fuels.

 

 

The recommended minimum safe

fine mist of fuel is sprayed into the

Do not use heavy fuels such as No. 2

 

distance is 10 feet. It is further

 

combustion chamber.

fuel oil or No. 2 Diesel. Using heavy

 

recommended that these enclosure

 

THE AIR SYSTEM

fuels will result in:

 

 

materials be of a fire retardant

 

 

 

 

 

 

 

 

nature. These enclosure materials

The motor turns the fan. The fan

• clogged fuel filter and nozzle

 

shall be securely fastened to

pushes air into and around the

• carbon build-up on spark plug

 

prevent them from igniting or from

combustion chamber. This air is heated

• the need of non-toxic anti-icer in

 

upsetting the heater due to wind

and provides a stream of clean, hot air.

 

fuel during very cold weather

 

action.

 

 

 

THE IGNITION SYSTEM

Minimum heater clearances from

IMPORTANT: Use a KEROSENE ONLY

The ignition control assembly provides

 

combustibles:

 

container. Be sure storage container is

 

 

power to the ignitor. This ignites the

 

Outlet: 8 Ft.

Sides: 4 Ft.

clean. Foreign matter such as rust, dirt, or

 

fuel/air mixture in the combustion

 

water will cause the flame-out control to

 

Top: 4 Ft.

Rear: 4 Ft.

 

chamber.

 

shut down heater. Foreign matter may also

Locate heater on a stable and level

THE FLAME-OUT CONTROL SYSTEM

require you to clean fuel system often.

 

surface while hot or running or a fire

 

This system causes the heater to shut

 

 

 

 

 

may occur.

 

 

 

 

 

When moving or storing heater, keep

down if the flame goes out.

 

 

 

 

 

 

 

 

 

 

heater in a level position or fuel

Combustion Chamber

 

 

 

 

 

spillage may occur.

 

Motor

Air Pump

Keep children and animals away

Ignitor

 

 

 

Air Intake

 

 

Fan

Filter

 

 

 

 

 

from heater.

• Unplug heater when not in use.

• This heater is equipped with a

Clean

 

 

 

Cool

 

thermostat, heater may start anytime.

 

 

 

Air In

 

Heated

 

 

 

 

Never use heater in living or sleep-

Air Out

 

 

 

 

 

 

 

 

 

 

ing areas.

 

 

 

 

 

Never block air inlet (rear) or air

 

 

 

 

Air

 

 

 

 

Output

 

outlet (front) of heater.

 

 

 

 

 

 

 

 

 

Filter

Never move, handle, refuel, or

 

 

 

 

 

 

service a hot, operating, or plugged-

 

 

 

 

 

 

in heater.

 

 

 

 

 

Never attach duct work to front or

Fuel

Nozzle

Fuel

Air Line

Ignition Control

 

rear of heater.

 

Tank

 

Filter

To Burner

Assembly

 

 

 

Air For Fuel

 

Air For Combus-

Fuel

 

 

 

System

 

tion and Heating

 

 

 

 

 

Figure 5 - Cross Section Operational View

104447

4

Image 4
Contents Specifications General SpecificationsDescription UnpackingElectrical Specifications Product IdentificationGeneral Safety Information Models 2E510E, 2E511E, 3E218E, and 3E219DGeneral Safety Information Theory of Operation Fuels Ventilation AssemblyOperation Maintenance Upper Shell RemovalFAN AIR OUTPUT, AIR INTAKE, and Lint FiltersPump Pressure Adjustment Fuel FilterIgnitor Remove ignitor screw with a 1/4Fuel and AIR Line Replacement and Proper Routing NozzleIgnition Control Assembly Pump RotorPreventative Maintenance Schedule Storing Transporting, or ShippingFor Replacement Parts, Call Hours a Day 365 Days a Year Motor and Pump Assembly for Models 2E510E and 2E511EBurner Head Assembly for All Models Figure Part 2E510E 2E511E Description Number Qty2E510E and 2E511E Replacement Parts List for Models 2E510E and 2E511E Models 2E510E and 2E511E Portable Oil-Fired Heaters3E218E Replacement Parts List for Model 3E218E Model 3E218E3E219D Replacement Parts List for Model 3E219D Model 3E219DMaintenance Kits AccessoriesWiring Diagram Ignition ControlTroubleshooting Chart See Ignition Control Assembly,Symptom Possible Causes Corrective Action Limited Warranty 2E510E, 2E511E, 3E218E, and 3E219D

2E511E, 2E510E, 3E219D specifications

The Dayton 3E219D, 2E511E, and 2E510E are air circulators that embody modern advancements in design and technology, offering exceptional performance and efficiency. Each model brings unique features, making them suitable for various applications, be it in residential, commercial, or industrial settings.

The Dayton 3E219D stands out for its powerful motor that delivers high air movement while maintaining quiet operation. It is equipped with a 3-speed motor, allowing users to select the desired airflow according to their preferences and environmental conditions. The durable construction ensures longevity, with a corrosion-resistant finish ideal for various environments. One of its notable characteristics is the ability to tilt, allowing targeted airflow to specific areas, enhancing comfort significantly.

In contrast, the Dayton 2E511E provides enhanced portability and versatility. With a lightweight design and built-in handle, it can easily be moved from one location to another. This unit also features a three-speed switch, which allows users to adjust airflow as needed. Additionally, the 2E511E is designed to be energy-efficient, making it an environmentally friendly choice that helps reduce electricity bills without compromising performance. Its compact size makes it an excellent choice for tight spaces, while still delivering powerful air circulation.

Meanwhile, the Dayton 2E510E is engineered for heavy-duty usage. This model is built to withstand rigorous operational demands, making it an ideal choice for industrial applications. The sturdy metal housing and protective grille enhance safety and durability even in challenging conditions. Similar to its counterparts, it features a three-speed setting, providing flexibility in airflow management. Furthermore, the 2E510E is designed to promote effective air circulation across larger areas, making it suitable for warehouses or manufacturing facilities.

Together, these three models exemplify Dayton's commitment to quality and performance. Whether you need a robust air circulator for an industrial setting, a portable solution for home use, or a versatile unit for medium applications, Dayton has addressed diverse consumer needs. The integration of energy-efficient designs, user-friendly features, and durable construction ensures that each model provides reliable and long-lasting performance, catering to various airflow requirements. With Dayton's offerings, users can enjoy enhanced comfort and improved air quality in any environment.