Dayton 3E219D, 2E510E, 2E511E Fuel and AIR Line Replacement and Proper Routing, Nozzle

Page 9

Dayton Operating Instructions and Parts Manual

Models 2E510E, 2E511E, 3E218E, and 3E219D

Maintenance (Continued)

5. Place plastic hex-body into vise and

lightly tighten.

FUEL AND AIR LINE REPLACEMENT AND PROPER ROUTING

Combustion

Chamber

Burner

Strap

Photocell

Bracket

Air Line

Hose

Nozzle/

Adapter

Assembly

Fuel Line

Hose

6. Carefully remove nozzle from the

nozzle adapter using 5/8" socket

wrench.

Nozzle

Face

Nozzle

Sleeve

Nozzle

1.

Remove upper shell (see page 6).

2.

Remove side cover screws using

 

5/16" nut driver.

3.

Remove side cover.

4.

Inspect fuel and air line hoses for

 

cracks and/or holes. If fuel line hose

 

is damaged, disconnect from

 

nozzle adapter (see Figure 18, 19,

 

or 20) and from fuel filter (see

 

page 7). If air line hose is damaged,

 

disconnect from nozzle adapter

 

(see Figure 18, 19, or 20) and from

Figure 20 - Removing Air and Fuel Line Hoses (150,000 Btu/Hr Model Only)

NOZZLE

1.Remove upper shell (See page 6).

2.Remove fan (See page 6).

3.Remove fuel and air line hoses from nozzle assembly (See Figure 18, 19, or 20).

4.Turn nozzle assembly 1/4 turn to left and pull toward motor to remove (See Figure 21).

Burner Strap

Nozzle

Assembly

Figure 21 - Removing Nozzle Assembly, All Models

Nozzle Adapter

Air Line

Fitting

Fuel Line

Fitting

Figure 22 - Nozzle and Nozzle Adapter, All Models

7.Blow compressed air through face of nozzle. This will free any dirt in nozzle area.

8.Inspect nozzle sleeve for damage.

9.Replace nozzle into nozzle adapter until nozzle seats. Tighten 1/3 turn more using 5/8" socket wrench (40- 45 inch-pounds).

10.Attach nozzle assembly to burner strap.

11.Attach fuel and airline hoses to nozzle adapter assembly. See Fuel and Air Line Replacement and Proper Routing.

12.Replace fan (See page 6).

13.Replace fan guard and upper shell.

barb fitting on pump end cover

(see Figure 23).

5. Install new air and/or fuel line.

Attach one end of air line hose to

barb fitting on pump end cover

(see Figure 23) and the other end

to nozzle adapter (see Figure 18,

19, or 20). Attach one end of fuel

line hose to fuel filter (see page 7)

and the other end to nozzle

adapter (see Figure 18, 19, or 20).

Note: Route hoses as shown in

Figure 18, 19, or 20 according to

Model. Hoses are not to touch

photocell bracket.

6. Replace side cover.

7. Replace upper shell and fan guard

(see page 6).

Pump End Cover Barb Fitting

Barb

 

Fitting

 

Air Hose

 

40/60,000 Btu/Hr

115,000 Btu/Hr

Models

Model

Figure 23 - Air Hose to Barb Fitting

®

104447

9

Image 9
Contents General Specifications SpecificationsDescription UnpackingProduct Identification Electrical SpecificationsModels 2E510E, 2E511E, 3E218E, and 3E219D General Safety InformationGeneral Safety Information Theory of Operation Fuels Assembly VentilationOperation Upper Shell Removal MaintenanceFAN AIR OUTPUT, AIR INTAKE, and Lint FiltersFuel Filter Pump Pressure AdjustmentRemove ignitor screw with a 1/4 IgnitorNozzle Fuel and AIR Line Replacement and Proper RoutingPump Rotor Ignition Control AssemblyStoring Transporting, or Shipping Preventative Maintenance ScheduleMotor and Pump Assembly for Models 2E510E and 2E511E For Replacement Parts, Call Hours a Day 365 Days a YearPart 2E510E 2E511E Description Number Qty Burner Head Assembly for All Models Figure2E510E and 2E511E Models 2E510E and 2E511E Portable Oil-Fired Heaters Replacement Parts List for Models 2E510E and 2E511E3E218E Model 3E218E Replacement Parts List for Model 3E218E3E219D Model 3E219D Replacement Parts List for Model 3E219DAccessories Maintenance KitsIgnition Control Wiring DiagramSee Ignition Control Assembly, Troubleshooting ChartSymptom Possible Causes Corrective Action 2E510E, 2E511E, 3E218E, and 3E219D Limited Warranty

2E511E, 2E510E, 3E219D specifications

The Dayton 3E219D, 2E511E, and 2E510E are air circulators that embody modern advancements in design and technology, offering exceptional performance and efficiency. Each model brings unique features, making them suitable for various applications, be it in residential, commercial, or industrial settings.

The Dayton 3E219D stands out for its powerful motor that delivers high air movement while maintaining quiet operation. It is equipped with a 3-speed motor, allowing users to select the desired airflow according to their preferences and environmental conditions. The durable construction ensures longevity, with a corrosion-resistant finish ideal for various environments. One of its notable characteristics is the ability to tilt, allowing targeted airflow to specific areas, enhancing comfort significantly.

In contrast, the Dayton 2E511E provides enhanced portability and versatility. With a lightweight design and built-in handle, it can easily be moved from one location to another. This unit also features a three-speed switch, which allows users to adjust airflow as needed. Additionally, the 2E511E is designed to be energy-efficient, making it an environmentally friendly choice that helps reduce electricity bills without compromising performance. Its compact size makes it an excellent choice for tight spaces, while still delivering powerful air circulation.

Meanwhile, the Dayton 2E510E is engineered for heavy-duty usage. This model is built to withstand rigorous operational demands, making it an ideal choice for industrial applications. The sturdy metal housing and protective grille enhance safety and durability even in challenging conditions. Similar to its counterparts, it features a three-speed setting, providing flexibility in airflow management. Furthermore, the 2E510E is designed to promote effective air circulation across larger areas, making it suitable for warehouses or manufacturing facilities.

Together, these three models exemplify Dayton's commitment to quality and performance. Whether you need a robust air circulator for an industrial setting, a portable solution for home use, or a versatile unit for medium applications, Dayton has addressed diverse consumer needs. The integration of energy-efficient designs, user-friendly features, and durable construction ensures that each model provides reliable and long-lasting performance, catering to various airflow requirements. With Dayton's offerings, users can enjoy enhanced comfort and improved air quality in any environment.