Samsung AQV24VBGN manual Insufficient ventilation may result in poor performance

Page 7

safety information

CAUTION SIGNS

This appliance is not intended for use by persons (including children) with reduced physical,sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Make sure that there are no obstacles or covers that block the air conditioner. Allow sufficient space for air circulation.

Insufficient ventilation may result in poor performance.

Make sure the voltage and frequency of the electric system are compatible with the air conditioner.

If a power outage occurs while the air conditioner is working, turn off the power source immediately.

Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.

The unit must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit breaker. An all pole disconnection from the power supply must be incorporated in the fixed wiring with a contact opening of >3mm.

After connecting the power cable between the indoor/outdoor unit, attach the cover of component box securely and make sure it is not loose.

For the power cable, use the grade of H07RN-F or H05RN-F materials.

The unbalanced power must be maintained within 10% of supply rating among whole indoor units.

If the power is unbalanced greatly, it may shorten the life of the condenser.

If the unbalanced power is exceeded over 10% of supply rating, the indoor unit is protected, stopped and the error mode indicates.

To protect the product from water and possible shock, you should keep the power cable and the connection cord of the indoor and outdoor units in the protection tube.

Connect the power cable to the auxiliary circuit breaker. You must keep the cable in a protection tube.

Keep distances of 50mm or more between power cable and communication cable.

Maximum length of power cable is decided within 10% of power drop. If it exceeds, you must consider another power supplying method.

The circuit breaker (MCCB, ELB) should be considered more capacity, if many indoor units are connected from one breaker.

Use solderless ring terminal to connect the power cable to the power terminal block. Use an appropriate screwdriver for tightening the terminal screws.

Over-tightening the terminal screws may break them.

Ensure the off-on and protection switches are properly installed.

Do not use the air conditioner if damaged. If problems occur, immediately stop operation and disconnect the plug from the power supply.

If the air conditioner will not be used for an extended period of time (for example, over several months), unplug the power from the wall.

Call the place of purchase or a contact center if repairs are needed.

Potential risk of fire or electric shock if disassembly or repairs are attempted by a non-qualified service technician.

If you smell burning plastic, hear strange sounds, or see smoke coming from the unit, unplug the air conditioner immediately and call a contact center.

Potential risk of fire or electric shock.

08_ safety information

India CST_IB_30951A_E_8.28.09.indd 8

2009-8-28 10:00:26

Image 7
Contents Model # Serial # Cool Summer OfferLook for Everywhere Compact and easy-to-use Cassette typeSafety Information Safety informationSevere Warning Signs Potential risk of electric shock, fire or unit malfunction Use an exclusive power source for the air conditioner Strong direct sunlight may deform the dust filter Wearing thick gloves can protect your hands Insufficient ventilation may result in poor performance Contents WAY Cassette Viewing your air conditionerMain parts Display Tips on Using AIR Conditioner Using your air conditionerCleaning the Exterior Cleaning and maintaining the air conditionerCleaning the Grille Cleaning the Filter Periodical checks Maintaining Your AIR ConditionerType Description Internal protections via the unit control systemAppendix TroubleshootingCooling Operation RangesTel 3030 8282, 1800 1800 3000 Web Site DB98-30951A2 Air Conditioner