Desa FGH-30NGB Operating Heater, To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 12

BLUE FLAME NATURAL GAS HEATER

OPERATING

HEATER

Continued

THERMOSTAT MODELS FAS-20BB AND FAS-30BB

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information column 3, page 11.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position.

Press in control knob for five (5) sec- onds (see Figure 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Ignitor Button

 

Control Knob

 

PILOT

LO

 

 

 

OFF

 

 

HI

 

Figure 16 - Control Knob In The OFF Position

Note: If pilot does not stay lit, refer to Troubleshooting, pages 15 through

17.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps

3through 7. Wait one (1) minute be- fore lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set control

knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 17 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modu- lating down in most cases.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 8).

2.Follow steps 1 through 5 under Light- ing Instructions .

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions, column 2.

5.Replace front panel.

12

105568

Image 12
Contents Blue Flame VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information Blue Flame Natural GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsLocate heater where moving ve- hicle will not hit it Check GAS TypeInstalling Heater to Wall Installing Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Connecting to GAS Supply Typical Inlet Pipe DiametersOperating HeaterManual Lighting Procedure Operating HeaterTo Turn OFF GAS To Appliance Thermostat Control OperationLighting Instructions What to do if YOU Smell GASCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atSpecifications Parts CentralsReplacement Parts Service HintsTechnical Service AccessoriesODS/Pilot Assembly Illustrated Parts BreakdownThermostat Models FAS-20BB FAS-30BB Parts List KEY Part Number for FAS-20BB FAS-30BB DescriptionNON-THERMOSTAT Models FA-20BB, FA-30BB, FGH-30NGB Parts Available not Shown Warranty Information

FA-30BB, FAS-20BB, FGH-30NGB, FA-20BB, FAS-30BB specifications

Desa FGH-30NGB, FA-20BB, FAS-30BB, FAS-20BB, and FA-30BB represent a compelling lineup of advanced heating solutions, engineered to cater to diverse consumer needs for efficient heating and functionality. Each model stands out with unique features and technologies that set them apart in the competitive market.

The FGH-30NGB model is particularly commendable for its innovative design and energy efficiency. It integrates advanced gas burner technology, which ensures optimal heat output while minimizing energy consumption. This model is equipped with an automatic ignition system, adding convenience for users who prioritize ease of use. Additionally, the FGH-30NGB features a robust safety mechanism, including automatic shut-off in case of overheating, which enhances user confidence.

In contrast, the FA-20BB model showcases versatility with its multifaceted heating settings. Ideal for both residential and commercial environments, this model incorporates state-of-the-art electronic controls that allow users to adjust temperatures with precision. The FA-20BB also prioritizes user comfort through its Quiet Mode operation, which significantly reduces noise during heating cycles, making it suitable for quiet settings like bedrooms and libraries.

The FAS-30BB takes technology a step further with its integration of smart features. This model is Wi-Fi enabled, allowing users to control the heater remotely through a mobile app. This capability is particularly advantageous for tech-savvy consumers who wish to manage their heating systems efficiently from anywhere. Moreover, the FAS-30BB boasts a sleek, modern design, making it an aesthetic addition to any space.

Meanwhile, the FAS-20BB offers a compact design without compromising heating power. Ideal for smaller spaces, it combines efficiency with a lightweight build, making it easy to move when needed. Its user-friendly digital interface provides valuable feedback and allows users to easily monitor performance.

Finally, the FA-30BB model caters to those needing a high-performance solution. With dual heating modes, this model stands out in versatility and effectiveness. It utilizes advanced thermal insulation technologies that enhance heat retention, ensuring maximum efficiency.

In conclusion, the Desa FGH-30NGB, FA-20BB, FAS-30BB, FAS-20BB, and FA-30BB models present a broad spectrum of features and technologies that address various heating requirements. From smart technology integration to energy-efficient designs, each model is crafted to offer performance, reliability, and user satisfaction in any setting.