Desa CRL3124PA/NA, CCL3018PA/NA, CCL3930PTB/NTB Optional Positioning Thermostat Sensing Bulb

Page 28

Optional Positioning

of Thermostat

Sensing Bulb

For Masonry and Factory- built Metal Fireplace

If your log set cycles to pilot, but the room tem- perature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb elsewhere, an adhesive- backed mounting clip is available.

Tools needed: 1/4" hex driver or socket

1.Remove logs. Locate the gas valve assembly and thermostat sensing bulb (see Figure 38).

2.With 1/4" hex driver or socket, loosen the ther- mostat screw. Carefully slide the thermostat sensing bulb out of the retaining clamp (see Figure 40).

Note: Do not remove the screw. Make sure you tighten the screw after removing the thermostat sensing bulb.

IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary.

3.The thermostat sensing bulb may be located to the lower right front side of fireplace. Determine location of sensing bulb, but do not mount sens- ing bulb until step 4. If you have a masonry fire- place, see Figure 41 for location. If you have a factory-built metal fireplace, see Figure 42 for location. If your fireplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 43).

Figure 39 - Adhesive-backed Mounting Clip

Capillary

Thermostat

Screw

 

Retaining

 

Clamp

 

 

Thermostat

 

Sensing

 

Bulb

Figure 40 - Removing Thermostat

Sensing Bulb

Thermostat

Sensing Bulb

Adhesive-backed

Mounting Clip

Figure 41- Locating Thermostat Sensing

Bulb on Masonry Fireplace

Thermostat

Sensing Bulb

Adhesive- backed Mounting Clip

 

 

Figure 42 - Locating Thermostat Sensing

Gas Valve

 

Bulb on Factory-built Metal Fireplace

Assembly

 

Thermostat

 

 

 

 

Sensing Bulb

 

 

Adhesive-backed

Mounting

Thermostat

Mounting Clip

 

Bracket

Sensing

 

 

Bulb

Glass Doors

Figure 38 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Figure 43 - Installing Thermostat Sensing

Bulb Behind Glass Doors

28

www.desatech.com

113097-01E

Image 28
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Local CodesProduct Features Product IdentificationUnpacking Air for Combustion VentilationAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow For Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeInstallation Installation and Clearances Vent-Free Operation OnlyAccessories, Mantel ClearancesInstalling Damper Clamp Accessory for Vented Operation Floor ClearancesInstalling Heater Base Assembly Installation Items NeededChimney Minimum Permanent Area of Various Standard Round FluesConnecting to GAS Supply Attaching Base Assembly to Fireplace Floor Dual Burner ModelPropane/LP Checking GAS ConnectionsNatural Pressure Testing Heater Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs CCL3930PTB/NTBInstalling Crossover Log #4 CCL3930PTB/NTB Shown Installing Back Log For Your Safety Read Before LIGHTING  Operating HeaterManually-Controlled Models  LIGHTING Instructions MANUAL Lighting Procedure Operating Heater VARIABLE Control Operation  TO Turn OFF GAS To ApplianceThermostat-Controlled Models For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Cleaning Maintenance Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Maintenance Service HintsTechnical Service When Gas Pressure Is Too LowTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Maintenance,Gas leak. See Warning Statement aboveOptional Positioning Thermostat Sensing Bulb For Masonry and Factory- built Metal FireplaceSpecifications Optional Positioning Thermostat Sensing BulbDual Burner Biltmore split OAK Models Single Burner Seasonal OAK ModelsIllustrated Parts Breakdown Parts List Variable Manually-Controlled biltmore split oak ModelsIllustrated Parts Breakdown Parts List Thermostatically-Controlled Biltmore Split Oak ModelsPeg positions vary according to model Left Top Crossover Log #5 3A 3B Variable Manually-Controlled Seasonal Oak Models Replacement Parts AccessoriesEquipment Shutoff Valve GA5010 Fireplace HoodParts Central Keep this Warranty Warranty InformationLimited Warranty Comfort Glow VENT-FREE GAS LOG Heaters

CCL3018PTA/NTA, RL2718PA/NA, CCL3924PA/NA, CCL3924PTA/NTA, CCL3930PTB/NTB specifications

Desa CCL3924PTA/NTA, CCL3018PTA/NTA, CCL3930PTB/NTB, CCL3924PA/NA, and CCL3018PA/NA are a lineup of advanced cooling units designed to meet diverse needs in thermal management for residential, commercial, and industrial applications. Each model brings together a blend of innovative technology and user-friendly features that ensure efficient performance and reliability.

The CCL3924PTA/NTA model is designed for high-performance cooling, offering a blend of efficiency and sustainable operation. Its inverter technology allows for variable speed control, leading to lower energy consumption and quieter operation. This model is particularly suited for larger spaces, providing consistent cooling throughout the environment while maintaining energy efficiency.

CCL3018PTA/NTA is a compact unit that excels in environments with space constraints. Despite its smaller size, it delivers robust cooling performance, making it ideal for residential settings or small office spaces. Its lightweight design and easy installation capabilities reduce downtime and allow for swift setup, while its smart thermostat controls enable precise temperature management.

For environments that require intensive cooling, the CCL3930PTB/NTB model stands out with its powerful compressor and larger cooling capacity. This unit is engineered for industrial applications, featuring heavy-duty components that ensure long operational life even in demanding conditions. Its multi-zone capability allows users to cool several areas simultaneously, providing tailored solutions for complex layouts.

The CCL3924PA/NA variant focuses on energy efficiency without compromising on cooling power. This model is equipped with advanced thermal insulation technology, minimizing heat exchange and enhancing its performance during peak usage. Users benefit from significant energy savings, making it an environmentally friendly choice for those concerned about carbon footprints.

Lastly, the CCL3018PA/NA brings versatility with its dual-function capability. This model not only serves as a cooling unit but can also function as a heater, making it a year-round solution for climate control. Its efficient heat pump technology makes it an ideal choice for locations with varying seasonal temperatures, ensuring comfort throughout the year.

In conclusion, the Desa lineup of cooling solutions combines cutting-edge technology, energy efficiency, and user-friendly features, catering to a wide array of applications and user needs. Each model has been engineered with a focus on durability and reliability, making them a smart investment for anyone looking to enhance their indoor climate control systems.