Desa DNV25PB, DNV40PB installation manual Locating Thermostat on Wall, Routing Thermostat Cable

Page 6

DYNAVENT®

DIRECT-VENT PROPANE/LP GAS HEATER

INSTALLATION

(Continued)

6.Attach thermostat to thermostat mount- ing plate with screws provided (see Fig- ure 4). IMPORTANT: Note mounting plate position in Figure 4. Correctly position mounting plate for your model furnace.

7.Insert thermostat mounting plate be- tween wall and cabinet flange. Line up top notch on mounting plate with top screw on flange (see Figure 5). IMPORTANT: Thermostat for 25,000 BTU/Hr model mounts on right side of furnace (see Figure 5). Thermostat for 40,000 BTU/Hr model mounts on left side of furnace (see Figure 5).

8.Insert screw in cabinet flange and ther- mostat mounting plate and tighten firmly.

IMPORTANT: Make sure thermostat wires do not touch combustion chamber.

 

.2

 

.3

 

.4

OFF

.5

 

.7

 

1.0

 

50

60

 

 

 

 

 

 

 

70

 

 

 

 

SOLID

 

 

80

90

 

 

STATE

 

 

 

 

 

 

 

 

 

 

50

60

 

 

 

IGNITION

40,000 BTU/Hr Models

 

70

 

 

90

 

 

80

 

 

 

 

 

 

 

.2

 

.3

 

.4

OFF

.5

 

.7

 

1.0

 

50

60

 

 

 

 

 

 

 

 

70

80

 

 

 

SOLID

 

 

 

90

 

 

STATE

 

 

 

 

 

 

 

 

 

 

50

60

 

 

 

IGNITION

 

 

70

 

 

 

 

 

 

80

 

 

 

 

 

 

90

25,000 BTU/Hr Models

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4 - Attaching Thermostat to Thermostat Mounting Plate

 

 

 

00

00

 

00

00

 

00

 

 

 

40,000 BTU/Hr Models

50

60

 

 

 

 

70

80

 

 

 

 

90

25,000 BTU/Hr Models

Figure 5 - Inserting Thermostat Mounting Plate Between Wall and Cabinet Flange

Locating Thermostat on Wall

1.Locate thermostat 4 1/2 to 5 feet above the floor on an inside wall away from any heat sources. The thermostat needs to sense average room temperature. Avoid the following:

HOT SPOTS

Concealed pipes or ducts Fireplaces

Registers

TV sets and radios Lamps or direct sunlight Kitchen

COLD SPOTS

Concealed pipes or ducts Stairwells (drafts) or doors (drafts) Unheated rooms on other side of wall

DEAD SPOTS

Behind doors Corners and alcoves

2.Before installing thermostat, inspect the wall, floor, and attic areas. Make sure there are no pipes, wiring, or anything else that would interfere with install- ing thermostat. Do not mount thermo- stat to stud. If there are any obstruc- tions, choose a new location.

3.Provide two 18-gauge insulated stranded wires for the thermostat wire. Also pro- vide two wire nuts, and two wall anchors. There is a red and a white thermostat wire coming from the furnace. The extra ther- mostat wires you furnish attach to these wires. Make sure you furnish a red and a white wire. This will insure correct hookup. Purchase enough thermostat wire to go from the furnace to the thermostat location. Do not cut and splice this wire. The thermostat wire must be unbroken.

Routing Thermostat Cable

All wiring must meet local codes. The fol- lowing instructions cover routing the wire through the attic. You can run wiring from a basement or crawl space.

1.Unplug furnace.

2.Before drilling hole in wall, drive a small finishing nail through ceiling directly above thermostat location. Pull nail out and push a small stiff wire through hole. This helps you locate thermostat mount- ing location when in attic.

3.In attic, locate stiff wire. Drill 1/2" hole in center of ceiling wall plate next to stiff wire. Remove wire.

4.Probe through drilled hole in wall plate with a stiff wire to make sure there are no pipes, wiring, or anything else blocking the way for thermostat wires. If you find blockage, choose new loca- tion for thermostat.

5.Drill a 1/2" hole through the wall at thermostat mounting location.

6.From attic, feed thermostat wires through hole in ceiling plate until wires reach thermostat location.

7.Make a small hook with a piece of stiff wire. Run wire hook through 1/2" hole in wall. Hook thermostat wires. Pull wires through hole in wall. Make sure 6" of wires stick out.

8.Drive a small finishing nail in ceiling above furnace.

25,000 BTU/Hr Model - Drive nail above right side of furnace.

40,000 BTU/Hr Model - Drive nail above left side of furnace. Pull nail out and push a small stiff wire through hole. This helps you locate wire routing location when in attic.

9.Repeat steps 3 and 4 above.

6

201839

Image 6
Contents OWNER’S Operation and Installation Manual DNV25PB DNV40PB For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DynaventLocal Codes Product FeaturesSpecifications UnpackingCheck GAS Type InstallationInstallation Items Locating FurnaceInstalling in Masonry Wall Installing ThermostatInstalling in Normal Frame Wall Creating Wall Opening and Mounting FurnaceLocating Thermostat on Wall Routing Thermostat CableConnecting to GAS Supply Connecting Furnace to Gas Supply at Front of FurnaceMounting the Thermostat to Wall Connecting Furnace to Gas Supply at Rear of Furnace Removing Screws on Lower Flange 40,000 BTU/Hr Model ShownProviding Gas Piping to Furnace ExamplePressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Furnace Gas Connections Performance CheckFor Your Safety Read Before Lighting Operating FurnaceOperating Instructions To Turn OFF GAS To Furnace Inspecting Burner FlameNormal Operating Sequence Thermostat Control OperationCleaning and Maintenance Troubleshooting Observed Problem Possible Cause RemedyIgnition Failures Observed Problem Possible Cause Wire and wire connections at probe Parts not Under Warranty Wiring Diagrams ReplacementParts Under Warranty PartsWhen Gas Pressure Is Too Low Service HintsTechnical Service When Gas Quality Is BadIllustrated Parts List Cabinet Assembly 25,000 BTU/HR ModelCabinet Assembly 40,000 BTU/HR Model Combustion Chamber Assembly 25,000 BTU/HR Model Combustion Chamber Assembly 40,000 BTU/HR Model Burner Assembly 25,000 BTU/HR Model Burner Assembly 40,000 BTU/HR Model Blower Assembly 25,000 BTU/HR Model Blower Assembly 40,000 BTU/HR Model 201839 Warranty Information

DNV40PB, DNV25PB specifications

Desa DNV25PB and DNV40PB are two advanced models in the range of DNV portable heaters renowned for their efficiency and innovative technology. These heaters are designed to provide reliable and effective heating solutions for various applications, from industrial settings to outdoor events.

One of the standout features of the DNV25PB and DNV40PB models is their robust construction, making them suitable for rigorous work environments. Both models are built with high-quality materials that ensure durability and resilience even in challenging conditions. This makes them an ideal choice for industries such as construction, warehouses, and agriculture, where reliable heating is essential.

The performance of the DNV heaters is enhanced by their powerful heating capacity. The DNV25PB model can deliver an impressive output of 25 kW, while the DNV40PB model boasts a strong 40 kW output. This substantial heating capability allows them to heat large spaces quickly and efficiently, providing comfort in less time and reducing energy costs. Additionally, both models come equipped with adjustable heating settings, allowing users to tailor the output to meet their specific needs.

These heaters incorporate advanced technologies that prioritize energy efficiency and safety. They are designed with smart control systems that monitor and adjust the heater's operation, optimizing fuel consumption while delivering consistent heat. Furthermore, safety features such as automatic shut-off mechanisms and overheating protection devices are integrated into both models, ensuring safe operation even in extended use.

Portability is another significant characteristic of the DNV25PB and DNV40PB models. Their compact design, coupled with built-in handles and wheels, allows for easy transport between different sites, making them highly versatile. Users can effortlessly relocate the heaters to adapt to changing conditions or requirements, enhancing their practicality.

In summary, the Desa DNV25PB and DNV40PB portable heaters are characterized by their powerful heating capabilities, robust construction, energy efficiency, and safety features. They are well-suited for various industrial and outdoor applications, offering flexibility and reliable performance. With their innovative technology and thoughtful design, these models stand out in the market, providing effective heating solutions to meet diverse needs. Whether for temporary heating at a construction site or providing warmth for outdoor gatherings, the DNV series offers dependable performance tailored to user requirements.