Desa DNV25PB, DNV40PB installation manual Wire and wire connections at probe

Page 18

DYNAVENT®

DIRECT-VENT PROPANE/LP GAS HEATER

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Ignition failures

5.

Burner cycles off and glo bar comes on

5.

A. Check flame sensing probe. Be sure

 

 

immediately, check the following:

 

probe is positioned in the burner

 

 

 

 

flame and glowing cherry red. Check

 

 

 

 

wire and wire connections at probe

 

 

 

 

and ignition control

 

 

 

 

B. If wire and wire connections okay,

 

 

 

 

check for voltage across brown and

 

 

 

 

orange wires at ignition control. If

 

 

 

 

no voltage, replace ignition control

 

 

 

 

C. If voltage present, check wiring and

 

 

 

 

wire connections at valve

 

 

 

 

D. If wire and wire connections okay,

 

 

 

 

replace valve

 

 

 

 

 

Excessive noise

1.

Blower out of balance

1.

Replace blower

 

2.

Motor hums

2.

Replace motor

 

 

 

 

 

Main burner will not cycle off

1.

Thermostat setting

1.

Check thermostat

 

2.

Gas valve stuck open

2.

Check gas valve. If stuck open, replace.

 

 

 

 

Do not attempt to repair valve!

 

 

 

 

 

Furnace will not operate

1.

Wiring connections or shorts

1.

Check all wiring to assure proper con-

 

 

 

 

nection or detect possible shorts

www.desatech.com

18

201839

Image 18
Contents OWNER’S Operation and Installation Manual DNV25PB DNV40PB For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DynaventLocal Codes Product FeaturesSpecifications UnpackingCheck GAS Type InstallationInstallation Items Locating FurnaceInstalling in Masonry Wall Installing ThermostatInstalling in Normal Frame Wall Creating Wall Opening and Mounting FurnaceLocating Thermostat on Wall Routing Thermostat CableConnecting to GAS Supply Connecting Furnace to Gas Supply at Front of FurnaceMounting the Thermostat to Wall Connecting Furnace to Gas Supply at Rear of Furnace Removing Screws on Lower Flange 40,000 BTU/Hr Model ShownProviding Gas Piping to Furnace ExamplePressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Furnace Gas Connections Performance CheckFor Your Safety Read Before Lighting Operating FurnaceOperating Instructions To Turn OFF GAS To Furnace Inspecting Burner FlameNormal Operating Sequence Thermostat Control OperationCleaning and Maintenance Troubleshooting Observed Problem Possible Cause RemedyIgnition Failures Observed Problem Possible Cause Wire and wire connections at probe Parts not Under Warranty Wiring Diagrams ReplacementParts Under Warranty PartsWhen Gas Pressure Is Too Low Service HintsTechnical Service When Gas Quality Is BadIllustrated Parts List Cabinet Assembly 25,000 BTU/HR ModelCabinet Assembly 40,000 BTU/HR Model Combustion Chamber Assembly 25,000 BTU/HR Model Combustion Chamber Assembly 40,000 BTU/HR Model Burner Assembly 25,000 BTU/HR Model Burner Assembly 40,000 BTU/HR Model Blower Assembly 25,000 BTU/HR Model Blower Assembly 40,000 BTU/HR Model 201839 Warranty Information

DNV40PB, DNV25PB specifications

Desa DNV25PB and DNV40PB are two advanced models in the range of DNV portable heaters renowned for their efficiency and innovative technology. These heaters are designed to provide reliable and effective heating solutions for various applications, from industrial settings to outdoor events.

One of the standout features of the DNV25PB and DNV40PB models is their robust construction, making them suitable for rigorous work environments. Both models are built with high-quality materials that ensure durability and resilience even in challenging conditions. This makes them an ideal choice for industries such as construction, warehouses, and agriculture, where reliable heating is essential.

The performance of the DNV heaters is enhanced by their powerful heating capacity. The DNV25PB model can deliver an impressive output of 25 kW, while the DNV40PB model boasts a strong 40 kW output. This substantial heating capability allows them to heat large spaces quickly and efficiently, providing comfort in less time and reducing energy costs. Additionally, both models come equipped with adjustable heating settings, allowing users to tailor the output to meet their specific needs.

These heaters incorporate advanced technologies that prioritize energy efficiency and safety. They are designed with smart control systems that monitor and adjust the heater's operation, optimizing fuel consumption while delivering consistent heat. Furthermore, safety features such as automatic shut-off mechanisms and overheating protection devices are integrated into both models, ensuring safe operation even in extended use.

Portability is another significant characteristic of the DNV25PB and DNV40PB models. Their compact design, coupled with built-in handles and wheels, allows for easy transport between different sites, making them highly versatile. Users can effortlessly relocate the heaters to adapt to changing conditions or requirements, enhancing their practicality.

In summary, the Desa DNV25PB and DNV40PB portable heaters are characterized by their powerful heating capabilities, robust construction, energy efficiency, and safety features. They are well-suited for various industrial and outdoor applications, offering flexibility and reliable performance. With their innovative technology and thoughtful design, these models stand out in the market, providing effective heating solutions to meet diverse needs. Whether for temporary heating at a construction site or providing warmth for outdoor gatherings, the DNV series offers dependable performance tailored to user requirements.