Desa CGS2718P Cleaning and Maintenance Trouble Shooting, ODS/PILOT and Burner, Logs

Page 23

CLEANING AND MAINTENANCE

TROUBLE-

SHOOTING

Note: All trouble- shooting items are listed in order of operation.

WARNING

WARNING ICON

G 001

Turn off heater and let cool before cleaning.

CAUTION

WARNING ICON

G 001

You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 19, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

WARNING

WARNING ICON

G 001

Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION

WARNING ICON

G 001

Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

When ignitor button

1.

Ignitor electrode not con-

1.

Reconnect ignitor cable

is pressed, there is no

 

nected to ignitor cable

 

 

spark at ODS/pilot

2.

Ignitor cable pinched or

2.

Free ignitor cable if

 

 

wet

 

pinched by any metal or

 

 

 

 

tubing. Keep ignitor

 

 

 

 

cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding

 

 

 

 

piezo ignitor to base

 

 

 

 

panel of log set. Nut is

 

 

 

 

located behind base

 

 

 

 

panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode broken

6.

Replace piezo ignitor

 

7.

Ignitor electrode posi-

7.

Replace piezo ignitor

 

 

tioned wrong

 

 

Continued 23

102989

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Pilot OperationConfined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building High traffic areas Windy or drafty areas InstallingCheck GAS Type Minimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Add lava rock around base of heater Installing LogsOperating Heater For Your Safety Read Before LightingVariable Control Operation Pilot Flame Pattern Inspecting BurnersLogs Cleaning and Maintenance Trouble ShootingTurn off heater and let cool before cleaning ODS/PILOT and BurnerTROUBLE- Shooting Cleaning and MainteRefer to Air for Com Statement at top Trouble ShootingModel Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown CGS2718P CGS3124P Parts ListKeep this Warranty Warranty Information

CGS2718P specifications

The Desa CGS2718P is a modern gas log set that combines state-of-the-art technology with aesthetically pleasing design, making it an ideal choice for homeowners seeking both functionality and beauty in their heating solutions. This model stands out for its efficiency and ease of use, providing effective heating while also offering a stylish centerpiece for any living space.

One of the main features of the Desa CGS2718P is its realistic flames and logs, designed to mimic the look of real wood-burning fireplaces. This is achieved through advanced ceramic fiber logs and a unique flame presentation that exudes warmth and authenticity, creating a cozy ambiance in any room. The logs are intricately designed to replicate the natural features found in real wood, providing a visually stunning experience.

The CGS2718P operates on natural gas, offering convenience and reliability compared to traditional wood-burning alternatives. This means less mess, lower maintenance, and the ability to control the heat output with greater precision. The unit is equipped with an easy-to-use manual control that allows homeowners to adjust their heating settings effortlessly.

In terms of technology, the Desa CGS2718P boasts an efficient heating system that maximizes warmth while minimizing energy consumption. The unit is designed with an innovative vent-free system, which means that no external venting is necessary. This makes it an excellent option for spaces where traditional chimneys would be impractical. Additionally, the vent-free design allows for higher heat retention, making the unit more efficient and eco-friendly compared to other systems.

Another notable characteristic of the CGS2718P is its safety features. It includes a built-in oxygen depletion sensor that automatically shuts off the gas supply if carbon dioxide levels become unsafe. This is vital for ensuring the safety of occupants in any home. Furthermore, the unit is designed for simple installation, making it accessible for both professionals and DIY enthusiasts alike.

In summary, the Desa CGS2718P is an impressive gas log set that offers a perfect blend of aesthetics, technology, and safety. With its realistic flame presentation, efficient heating capability, and modern safety features, it presents a compelling option for anyone looking to enhance their home heating experience. Whether for cozy evenings or as a decorative feature in your living space, the CGS2718P is sure to deliver warmth and beauty for years to come.