Desa CGS2718P Installing, Check GAS Type, High traffic areas Windy or drafty areas

Page 8

INSTALLING

8

NOTICE

A qualified service person must install heater. Follow all local codes.

NOTICE

State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes.

WARNING

Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

WARNING

WARNING ICON

G 001

Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING

WARNING ICON

G 001

Never install the heater

in a bedroom or bathroom except as a vented appliance (see page 13)

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION

WARNING ICON

G 001

This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

CHECK GAS TYPE

Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.

102989

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information 001 Local Codes Unpacking Product Features Safety PilotOperation Piezo Ignition SystemAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building High traffic areas Windy or drafty areas InstallingCheck GAS Type Minimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply Attaching Base Assembly to Fireplace FloorExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig Installing Logs Add lava rock around base of heaterFor Your Safety Read Before Lighting Operating HeaterVariable Control Operation Inspecting Burners Pilot Flame PatternCleaning and Maintenance Trouble Shooting Turn off heater and let cool before cleaningODS/PILOT and Burner LogsCleaning and Mainte TROUBLE- ShootingRefer to Air for Com Trouble Shooting Statement at topModel Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Breakdown Parts List CGS2718P CGS3124PWarranty Information Keep this Warranty

CGS2718P specifications

The Desa CGS2718P is a modern gas log set that combines state-of-the-art technology with aesthetically pleasing design, making it an ideal choice for homeowners seeking both functionality and beauty in their heating solutions. This model stands out for its efficiency and ease of use, providing effective heating while also offering a stylish centerpiece for any living space.

One of the main features of the Desa CGS2718P is its realistic flames and logs, designed to mimic the look of real wood-burning fireplaces. This is achieved through advanced ceramic fiber logs and a unique flame presentation that exudes warmth and authenticity, creating a cozy ambiance in any room. The logs are intricately designed to replicate the natural features found in real wood, providing a visually stunning experience.

The CGS2718P operates on natural gas, offering convenience and reliability compared to traditional wood-burning alternatives. This means less mess, lower maintenance, and the ability to control the heat output with greater precision. The unit is equipped with an easy-to-use manual control that allows homeowners to adjust their heating settings effortlessly.

In terms of technology, the Desa CGS2718P boasts an efficient heating system that maximizes warmth while minimizing energy consumption. The unit is designed with an innovative vent-free system, which means that no external venting is necessary. This makes it an excellent option for spaces where traditional chimneys would be impractical. Additionally, the vent-free design allows for higher heat retention, making the unit more efficient and eco-friendly compared to other systems.

Another notable characteristic of the CGS2718P is its safety features. It includes a built-in oxygen depletion sensor that automatically shuts off the gas supply if carbon dioxide levels become unsafe. This is vital for ensuring the safety of occupants in any home. Furthermore, the unit is designed for simple installation, making it accessible for both professionals and DIY enthusiasts alike.

In summary, the Desa CGS2718P is an impressive gas log set that offers a perfect blend of aesthetics, technology, and safety. With its realistic flame presentation, efficient heating capability, and modern safety features, it presents a compelling option for anyone looking to enhance their home heating experience. Whether for cozy evenings or as a decorative feature in your living space, the CGS2718P is sure to deliver warmth and beauty for years to come.