Desa CGS10P, CG6P, CG10P installation manual Maintenance

Page 15

OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice is clogged

1.

Clean burner orifice (see Cleaning and

 

 

 

 

Maintenance, page 13) or replace burner

 

 

 

 

orifice

 

2.

Burner orifice diameter is too small

2.

Replace burner orifice

 

3.

Inlet gas pressure is too low

3.

Contact local propane/LP gas company

 

 

 

 

 

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner orifice (see Cleaning and

 

 

 

 

Maintenance, page 13) or replace burner

 

 

 

 

orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner orifice (see Cleaning and

 

 

 

 

Maintenance, page 13) or replace burner

 

 

 

 

orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Yellow flame during burner combustion

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

Maintenance, page 13)

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP gas company

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

 

 

operation

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HIGH position

1.

Turn control knob to LOW position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas checked by local propane/

 

 

 

 

LP gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see Figure 4, page 7)

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 13) or replace burner orifice

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

White powder residue forming within the burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

Continued

107295

15

Image 15
Contents What to do if YOU Smell GAS Blue Flame VENT-FREE PROPANE/LP GAS HeaterPROPANE/LP GAS Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Marking Screw Locations Installing Bottom Mounting ScrewsRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallTions using 9/64 drill bit Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections To Turn OFF GAS To Appliance Manual Lighting ProcedureOperating Heater Lighting InstructionsThermostat Control Operation For Your Safety Read Before LightingInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Service Publications SpecificationsTechnical Service Service HintsParts not Under Warranty AccessoryReplacement Parts Parts Under WarrantyHeater & Fireplace Store Cans Unlimited, Inc Parts CentralsBaltimore Electric Washer Equipment Co Dayton Hardware Tarantin Tank CoIllustrated Parts List ODS Pilot AssemblyCG10P Parts Available not Shown CG6P KEY CG6P Description QTY CGS10P KEY CGS10P Description QTY Warranty Information

CG10P, CG6P, CGS10P specifications

Desa CGS10P, CG10P, and CG6P represent a line of advanced generator sets designed to meet the demanding energy needs of various applications, including residential, commercial, and industrial use. Their reliability and performance make them a popular choice among consumers looking for stable power solutions.

One of the standout features of the Desa CGS series is their robust engine technology. Each model is equipped with high-quality engines designed for efficiency and durability. The CGS10P, for example, features a powerful engine that delivers a substantial output, making it suitable for larger power requirements. The CG10P and CG6P, while slightly lower in output, still provide dependable power for most everyday applications.

The generators are equipped with advanced inverter technology, which allows them to produce clean and stable electricity. This is essential for powering sensitive electronics and appliances without the risk of surges or fluctuations that could lead to damage. The inverter technology also contributes to improved fuel efficiency, allowing users to maximize their runtime while minimizing fuel costs.

Portability is another critical characteristic of the Desa CGS series. These generators are designed with compactness in mind, making them easy to transport and store. Many models come with built-in handles and lightweight designs, allowing users to move them effortlessly for outdoor activities, camping, or emergency power situations.

The noise level of the Desa CGS series has been optimized to ensure a quieter operation compared to traditional generators. This acoustic engineering means that users can rely on these generators for power without disturbing neighbors or creating an unbearable noise during operation.

Safety features are paramount in the design of these generators. Each model includes automatic shut-off mechanisms that activate in case of low oil pressure or overheating, ensuring the longevity of the unit and the safety of users. Additionally, the CGS series often incorporates multiple outlets, providing versatility for connecting various devices.

In summary, the Desa CGS10P, CG10P, and CG6P generators combine advanced engine technology, inverter capabilities, and user-friendly design, making them ideal for diverse power needs. Their reliability, fuel efficiency, and safety features position them as excellent choices for anyone in need of a dependable power supply. Whether for home use, outdoor events, or as a backup during outages, these generators are equipped to handle a variety of situations efficiently.