Desa CG6P, CGS10P, CG10P installation manual Blue Flame VENT-FREE PROPANE/LP GAS Heater

Page 1

BLUE FLAME VENT-FREE PROPANE/LP GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

CG6P

CG10P

CGS10P

10,000 and 6,000 Btu/Hr

Thermostat and

Non-Thermostat Models

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal in- jury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installa- tion, adjustment, alteration, service, or maintenance can cause injury or property dam- age. Refer to this manual for correct installation and opera- tional procedures. For assis- tance or additional informa- tion consult a qualified in- staller, service agency, or the gas supplier.

WARNING:Thisisanunvented gas-firedheater.Itusesair(oxy- gen) from the room in which it is installed. Provisions for ad- equate combustion and venti- lation air must be provided. Refer to Air For Combustion and Ventilation on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS Blue Flame VENT-FREE PROPANE/LP GAS HeaterPROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Removing Front Panel Of Heater Installing Bottom Mounting ScrewsMethods For Attaching Mounting Bracket To Wall Marking Screw LocationsTions using 9/64 drill bit Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Operating Heater Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceThermostat Control Operation For Your Safety Read Before LightingInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsService Hints Service PublicationsReplacement Parts AccessoryParts Under Warranty Parts not Under WarrantyBaltimore Electric Washer Equipment Co Dayton Hardware Parts CentralsTarantin Tank Co Heater & Fireplace Store Cans Unlimited, IncODS Pilot Assembly Illustrated Parts ListCG10P Parts Available not Shown CG6P KEY CG6P Description QTY CGS10P KEY CGS10P Description QTY Warranty Information

CG10P, CG6P, CGS10P specifications

Desa CGS10P, CG10P, and CG6P represent a line of advanced generator sets designed to meet the demanding energy needs of various applications, including residential, commercial, and industrial use. Their reliability and performance make them a popular choice among consumers looking for stable power solutions.

One of the standout features of the Desa CGS series is their robust engine technology. Each model is equipped with high-quality engines designed for efficiency and durability. The CGS10P, for example, features a powerful engine that delivers a substantial output, making it suitable for larger power requirements. The CG10P and CG6P, while slightly lower in output, still provide dependable power for most everyday applications.

The generators are equipped with advanced inverter technology, which allows them to produce clean and stable electricity. This is essential for powering sensitive electronics and appliances without the risk of surges or fluctuations that could lead to damage. The inverter technology also contributes to improved fuel efficiency, allowing users to maximize their runtime while minimizing fuel costs.

Portability is another critical characteristic of the Desa CGS series. These generators are designed with compactness in mind, making them easy to transport and store. Many models come with built-in handles and lightweight designs, allowing users to move them effortlessly for outdoor activities, camping, or emergency power situations.

The noise level of the Desa CGS series has been optimized to ensure a quieter operation compared to traditional generators. This acoustic engineering means that users can rely on these generators for power without disturbing neighbors or creating an unbearable noise during operation.

Safety features are paramount in the design of these generators. Each model includes automatic shut-off mechanisms that activate in case of low oil pressure or overheating, ensuring the longevity of the unit and the safety of users. Additionally, the CGS series often incorporates multiple outlets, providing versatility for connecting various devices.

In summary, the Desa CGS10P, CG10P, and CG6P generators combine advanced engine technology, inverter capabilities, and user-friendly design, making them ideal for diverse power needs. Their reliability, fuel efficiency, and safety features position them as excellent choices for anyone in need of a dependable power supply. Whether for home use, outdoor events, or as a backup during outages, these generators are equipped to handle a variety of situations efficiently.