IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, elec- trical shock, and carbon monox- ide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to pro- pane/LP gas. The odor helps you detect a propane/LP gas leak. However, the odor added to propane/LP gas can fade. Propane/LP gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will re- main hot for a time after shut- down. Allow surface to cool be- fore touching.

Carefully supervise young chil- dren when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.This heater shall not be installed in a bedroom or bathroom.

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6.

6.Keep all air openings in the front and bottom of heater clear and free of de- bris. This will insure enough air for proper combustion.

7.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

10.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

11.Turn off heater and let cool before ser- vicing. Only a qualified service person should service and repair heater.

12.Operating heater above elevations of 4,500 feet could cause pilot outage.

13.To prevent performance problems, do not use propane/LP fuel tank of less than than 100 lbs. capacity.

2

104412

Image 2
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information BLUE-FLAME VENT-FREE PROPANE/LP GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating HeaterInstalling Heater to Wall Installing Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsReplacement Parts Service HintsODS/PILOT Illustrated Parts BreakdownRP30E Parts List KEY Part Number Description QTYCGP20B CGP20LB 098306-02 Floor Mounting Stand AccessoriesEquipment Shutoff Valve GA5010 Parts Centrals FBDLimited Warranty Comfort Glow VENT-FREE Heaters International

RP30E, CGP20B, CGP20LB specifications

Desa CGP20B, CGP20LB, and RP30E represent a series of versatile and robust generators designed to meet diverse power needs across various applications. These models blend advanced technology with user-friendly features, making them suitable for both residential and commercial use.

The Desa CGP20B is notable for its compact design and high-efficiency performance. It is equipped with a powerful engine that ensures reliable power output, making it ideal for backup power during outages or for powering tools at job sites. The generator features a large capacity fuel tank that allows for extended run times, making it a practical choice for extended use. Additionally, the CGP20B comes with a user-friendly control panel, which includes clearly marked outlets, making it easy to connect appliances and devices.

The CGP20LB model stands out with its low noise operation, making it one of the quieter options in the generator market. This is particularly beneficial for residential areas or during camping trips. Its lightweight design enhances portability, allowing users to transport it with ease. The unit is also equipped with a variety of safety features, including overload protection and a low oil shutoff mechanism, which helps to extend the lifespan of the generator.

On the other hand, the RP30E is designed for more heavy-duty applications. This model boasts a higher power output and is suitable for larger appliances, industrial tools, and construction sites. The RP30E incorporates advanced inverter technology, which provides clean and stable power, making it safe for sensitive electronics. Its digital display panel provides real-time monitoring of power consumption and operational status, ensuring users are always informed about the generator's performance.

All three models feature sturdy construction, ensuring durability and reliability in challenging environments. They also come with multiple outlet options, including 120V and 240V outlets, which enhances their versatility. Fuel efficiency is a key characteristic across the range, allowing users to save on operational costs while minimizing environmental impact.

In conclusion, the Desa CGP20B, CGP20LB, and RP30E generators offer an impressive array of features and technologies tailored to meet varied power requirements. Whether for residential backup, recreational use, or industrial applications, these generators deliver reliability, efficiency, and ease of use, making them valuable assets for any user.