WARNING: This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided for adequate combustion and venti- lation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to Deter- mining Fresh-Air Flow for Heater Lo- cation, page 5.

Confined and Unconfined Space

The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

4

104412

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information BLUE-FLAME VENT-FREE PROPANE/LP GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Installing Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Typical Inlet Pipe DiametersFor Your Safety Read Before Lighting Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Operating HeaterManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications Replacement PartsTechnical Service Service HintsRP30E Illustrated Parts BreakdownODS/PILOT Parts List KEY Part Number Description QTYCGP20B CGP20LB 098306-02 Equipment Shutoff Valve GA5010 AccessoriesFloor Mounting Stand Parts Centrals FBDLimited Warranty Comfort Glow VENT-FREE Heaters International

RP30E, CGP20B, CGP20LB specifications

Desa CGP20B, CGP20LB, and RP30E represent a series of versatile and robust generators designed to meet diverse power needs across various applications. These models blend advanced technology with user-friendly features, making them suitable for both residential and commercial use.

The Desa CGP20B is notable for its compact design and high-efficiency performance. It is equipped with a powerful engine that ensures reliable power output, making it ideal for backup power during outages or for powering tools at job sites. The generator features a large capacity fuel tank that allows for extended run times, making it a practical choice for extended use. Additionally, the CGP20B comes with a user-friendly control panel, which includes clearly marked outlets, making it easy to connect appliances and devices.

The CGP20LB model stands out with its low noise operation, making it one of the quieter options in the generator market. This is particularly beneficial for residential areas or during camping trips. Its lightweight design enhances portability, allowing users to transport it with ease. The unit is also equipped with a variety of safety features, including overload protection and a low oil shutoff mechanism, which helps to extend the lifespan of the generator.

On the other hand, the RP30E is designed for more heavy-duty applications. This model boasts a higher power output and is suitable for larger appliances, industrial tools, and construction sites. The RP30E incorporates advanced inverter technology, which provides clean and stable power, making it safe for sensitive electronics. Its digital display panel provides real-time monitoring of power consumption and operational status, ensuring users are always informed about the generator's performance.

All three models feature sturdy construction, ensuring durability and reliability in challenging environments. They also come with multiple outlet options, including 120V and 240V outlets, which enhances their versatility. Fuel efficiency is a key characteristic across the range, allowing users to save on operational costs while minimizing environmental impact.

In conclusion, the Desa CGP20B, CGP20LB, and RP30E generators offer an impressive array of features and technologies tailored to meet varied power requirements. Whether for residential backup, recreational use, or industrial applications, these generators deliver reliability, efficiency, and ease of use, making them valuable assets for any user.