DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = ____________________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

 

______________________ Btu/Hr

 

 

 

 

Gas water heater*

 

______________________ Btu/Hr

Example:

 

 

 

Gas furnace

 

______________________ Btu/Hr

 

 

 

 

Gas water heater

 

40,000

Btu/Hr

Vented gas heater

 

______________________ Btu/Hr

 

 

Vent-free heater

+

20,000

Btu/Hr

Gas fireplace logs

 

______________________ Btu/Hr

 

 

=

 

 

+

Total

60,000

Btu/Hr

Other gas appliances*

______________________ Btu/Hr

 

 

 

 

Total

=

______________________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_____________ Btu/Hr (maximum the space can support)

_____________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 60,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable local codes.

Continued

104412

5

Image 5
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualBLUE-FLAME VENT-FREE PROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationCheck GAS Type Locating HeaterInstalling Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts SpecificationsTechnical Service Service HintsODS/PILOT Illustrated Parts BreakdownRP30E KEY Part Number Description QTY Parts ListCGP20B CGP20LB 098306-02 Floor Mounting Stand AccessoriesEquipment Shutoff Valve GA5010 FBD Parts CentralsInternational Limited Warranty Comfort Glow VENT-FREE Heaters

RP30E, CGP20B, CGP20LB specifications

Desa CGP20B, CGP20LB, and RP30E represent a series of versatile and robust generators designed to meet diverse power needs across various applications. These models blend advanced technology with user-friendly features, making them suitable for both residential and commercial use.

The Desa CGP20B is notable for its compact design and high-efficiency performance. It is equipped with a powerful engine that ensures reliable power output, making it ideal for backup power during outages or for powering tools at job sites. The generator features a large capacity fuel tank that allows for extended run times, making it a practical choice for extended use. Additionally, the CGP20B comes with a user-friendly control panel, which includes clearly marked outlets, making it easy to connect appliances and devices.

The CGP20LB model stands out with its low noise operation, making it one of the quieter options in the generator market. This is particularly beneficial for residential areas or during camping trips. Its lightweight design enhances portability, allowing users to transport it with ease. The unit is also equipped with a variety of safety features, including overload protection and a low oil shutoff mechanism, which helps to extend the lifespan of the generator.

On the other hand, the RP30E is designed for more heavy-duty applications. This model boasts a higher power output and is suitable for larger appliances, industrial tools, and construction sites. The RP30E incorporates advanced inverter technology, which provides clean and stable power, making it safe for sensitive electronics. Its digital display panel provides real-time monitoring of power consumption and operational status, ensuring users are always informed about the generator's performance.

All three models feature sturdy construction, ensuring durability and reliability in challenging environments. They also come with multiple outlet options, including 120V and 240V outlets, which enhances their versatility. Fuel efficiency is a key characteristic across the range, allowing users to save on operational costs while minimizing environmental impact.

In conclusion, the Desa CGP20B, CGP20LB, and RP30E generators offer an impressive array of features and technologies tailored to meet varied power requirements. Whether for residential backup, recreational use, or industrial applications, these generators deliver reliability, efficiency, and ease of use, making them valuable assets for any user.