Desa CGN10TLA, CGN10TA installation manual Inspecting Burner, Cleaning and Maintenance

Page 12

CGN10TA and CGN10TLA

VENT-FREE NATURAL GAS HEATER

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pat- tern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 18

turn heater off (see To Turn Off Gas to Appliance, page 11)

see Troubleshooting, pages 13 through 15

Pilot Burner

Thermocouple

Figure 17 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

Figure 18 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

NOTICE: Do not mistake orange flames with yellow tipping. Dust or other fine particles enter the heater and burn causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 11)

see Troubleshooting, pages 13 through 15

1/2 GLASS HEIGHT

Figure 19 - Correct Burner Flame Pattern

Yellow

Tipping

1/2 GLASS HEIGHT

Figure 20 - Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING BURNER PILOT AIR INLET HOLE

We recommend that you clean the unit every 2,500hoursofoperationoreverythreemonths.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 21). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot Air Inlet Hole

Pilot Assembly

Figure 21 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow in- structions at bottom of this page.

ODS/PILOT AND BURNER

Exterior

• Use a soft cloth dampened with a mild

ORIFICE

soap and water mixture. Wipe the cabi-

• Use a vacuum cleaner, pressurized air,

net to remove dust.

or small, soft bristled brush to clean.

 

12

104267

Image 12
Contents CGN10TA CGN10TLA What to do if YOU Smell GASSafety Information VENT-FREE Natural GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpacesAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installing Two Mounting Screws Installing Bottom Mounting ScrewPlacing Heater On Mounting Screws Removing Front Panel Of HeaterConnecting to GAS Supply Gas ConnectionFor Your Safety Read Before Lighting Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connection Operating HeaterManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS to Appliance Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance , Gas leak. See Warning statement at Technical Service Service HintsAccessory Replacement PartsParts Central Illustrated Parts Breakdown CGN10TACGN10TLA Parts List CGN10TA CGN10TLAWarranty Information