Desa CGN10TLA, CGN10TA Technical Service, Service Hints, Accessory, Replacement Parts

Page 16

CGN10TA and CGN10TLA

VENT-FREE NATURAL GAS HEATER

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

You can also visit DESA International’s technical service web site at www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

When Gas Quality Is Bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

ACCESSORY

Purchase these heater accessories from your local dealer. If they cannot supply this ac- cessories, either contact your nearest Parts Central (see page 17) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information. You can also write to the address listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE - GA5010

Equipment shutoff valve with 1/8" NPT tap.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealer from whom you purchased this product. If they cannot sup- ply original replacement part(s), call DESA International’s Technical Service Depart- ment at 1-800-323-5190 for referral infor- mation.

When contacting your dealer or DESA In- ternational, have ready:

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

SERVICE

PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

SPECIFICATIONS

 

CGN10TA/CGN10TLA

Btu (Variable)

5,000/10,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (inches of water)

 

Maximum

10.5"

Minimum

5"

Dimensions, Inches (H x W x D)

 

Heater (Including knobs and grill)

21 1/2 x 13 1/2 x 7

Carton

25 1/4 x 16 3/4 x 7 1/2

Weight (pounds)

 

Shipping

19

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they cannot supply original replacement part(s), either contact your nearest Parts Central (see page 17) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information.

When calling DESA International, have ready:

model number of your heater

the replacement part number

16

104267

Image 16
Contents CGN10TA CGN10TLA What to do if YOU Smell GASSafety Information VENT-FREE Natural GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpacesDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installing Two Mounting Screws Installing Bottom Mounting ScrewPlacing Heater On Mounting Screws Removing Front Panel Of HeaterConnecting to GAS Supply Gas ConnectionFor Your Safety Read Before Lighting Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connection Operating HeaterManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS to Appliance Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance , Gas leak. See Warning statement at Technical Service Service HintsAccessory Replacement PartsParts Central CGN10TA Illustrated Parts BreakdownCGN10TLA Parts List CGN10TA CGN10TLAWarranty Information