Desa CGN10TA Lighting Instructions, To Turn OFF GAS to Appliance, Thermostat Control Operation

Page 11
C-clockwise

OWNER’S MANUAL

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety informa- tion, page 10.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clock-

wise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, includ- ing near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation on page 10. If you don’t smell gas, go to the next step.

5.Turn control knob counterclock-

wise to the PILOT posi- tion. Press in control knob for five

(5) seconds (see Figure 15).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is at- tached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ig- nitor button until pilot lights.

Note: If pilot does not stay lit, re- fer to Troubleshooting, pages 13 through 15. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pi- lot with match, see Manual Light- ing Procedure, column 3.

7.Keep control knob pressed in for 30 seconds after lighting pilot. Af- ter 30 seconds, release control knob.

If control knob does not pop up when released, contact a quali- fied service person or gas sup- plier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Control

Button Knob

PILOT

LO

OFF

 

HI

 

IGNITOR

Figure 15 - Control Knob In The OFF Position

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 16 - Pilot

TO TURN OFF GAS TO

APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 8).

2.Follow steps 1 through 5 under Light- ing Instructions, column 1.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions, column 2.

5.Replace front panel.

104267

11

Image 11
Contents What to do if YOU Smell GAS CGN10TA CGN10TLAVENT-FREE Natural GAS Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Spaces AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Removing Front Panel Of Heater Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Placing Heater On Mounting ScrewsGas Connection Connecting to GAS SupplyOperating Heater For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionThermostat Control Operation Manual Lighting ProcedureLighting Instructions To Turn OFF GAS to ApplianceInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance , Gas leak. See Warning statement at Replacement Parts Technical ServiceService Hints AccessoryParts Central CGN10TLA Illustrated Parts BreakdownCGN10TA CGN10TA CGN10TLA Parts ListWarranty Information