Desa CGP18C, RP30C installation manual Marking Screw Locations, Attaching Mounting Bracket To Wall

Page 12

12

INSTALLING TO WALL

Continued

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level.

WARNING

Maintain minimum clearances shown in Figure 7. If you can, provide greater clearances from floor and joining wall.

2.Mark screw locations on wall (see Figure 7).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

11"

16"

7 1/4"

16"

Min.

 

Min.

 

AdjoiningWall

 

AdjoiningWall

Only Insert Mounting

 

Only Insert Mounting

32 1/2"

 

18 3/4"

Screws Through Last

Min.

 

Screws Through Last

Min.

Hole On Each End

 

Hole On

Each End

Floor

 

 

 

Floor

 

 

 

 

 

 

 

 

RP30C

 

 

CGP18C

 

Figure 7 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 8.

Figure 8 - Folding Anchor

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

101805

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Product Identification Local CodesUnpacking ProductAIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterCeiling Floor16 3/ 4 RP30C CGP18CInstalling Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS Qualified service person must connect heater to gas supplySupply Follow all local codesPressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingHeater What to do if YOU Smell GASOperating Heater PilotOperating InspectingBurner Pilot Flame PatternInspecting Burner Burner Flame PatternCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting Trouble FromIng statement at TopTechnical Service Service HintsRP30C CGP18C Replacement Parts Centrals Parts Under WarrantyParts Not Under Warranty Accessories Manual ShutoffFloor Mounting RP30C RP30C Parts List KEY Part Number Description QTYCGP18C CGP18C Parts List Warranty Information Limited Warranty Comfort Glow VENT-FREE Heaters

RP30C, CGP18C specifications

Desa RP30C and CGP18C are two innovative models in the range of residential heat and air solutions designed to enhance home comfort while promoting energy efficiency. Both units stand out due to their advanced features, reliable technology, and user-friendly characteristics.

The Desa RP30C is a powerful, high-efficiency propane heater that delivers exceptional warmth and comfort. It is designed for spaces up to 1,000 square feet, making it suitable for various applications, including homes, workshops, and garages. This heater operates quietly and has an adjustable thermostat that allows users to maintain their desired temperature easily. The RP30C features a durable construction, with a robust chassis and a sleek design that integrates well into different settings.

One of the main highlights of the RP30C is its safety features, which include an automatic shut-off mechanism in case of overheating, ensuring user peace of mind. Additionally, it utilizes a catalytic combustion process that not only maximizes heat production but also minimizes pollutant emissions, making it an environmentally responsible choice.

On the other hand, the CGP18C is a portable gas-powered generator designed for convenience and reliability during power outages or outdoor activities. With an 18,000-watt peak output, this generator can power multiple appliances efficiently. It is built to withstand various environmental conditions, featuring a weather-resistant casing and solid wheels for easy mobility.

The CGP18C employs advanced inverter technology that ensures clean and stable power, making it safe for sensitive devices such as computers and medical equipment. Its user-friendly control panel simplifies operation, while a built-in fuel gauge allows users to monitor their remaining fuel levels effectively. Moreover, the generator is equipped with multiple outlet options, accommodating various plug types to meet diverse power needs.

Both the Desa RP30C and CGP18C exemplify modern engineering, combining functionality, efficiency, and ease of use. They are ideal for anyone seeking effective heating solutions or dependable power generation, making them essential additions for home and outdoor use. With these products, users can enjoy enhanced comfort and reliability in their daily lives.