Desa CGP18C, RP30C installation manual Ing statement at, Top

Page 24

24

TROUBLE- SHOOTING

Continued

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Heater produces a

1.

Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling

 

excessive, contact

or shut off

 

 

 

qualified service person

 

 

 

 

 

Heater produces

1.

Heater burning vapors

1.

Ventilate room. Stop

unwanted odors

 

from paint, solvents,

 

using odor causing

 

 

glues, etc. See IMPOR-

 

products while heater is

 

 

TANT statement above

 

running

 

2.

Low fuel supply

2.

Refill supply tank

 

3.

Gas leak. See Warn-

3.

Locate and correct all

 

 

ing statement at

 

leaks (see Checking Gas

 

 

top of page

 

Connections, page 15)

 

 

 

 

 

Heater shuts off in

1.

Not enough fresh air is

1.

Open window and/or

use (ODS operates)

 

available

 

door for ventilation

 

2.

Low line pressure

2.

Contact local propane/

 

 

 

 

LP gas company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 21)

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position

 

top of page

 

Connections, page 15)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during

1.

Foreign matter be-

1.

Take apart gas tubing

combustion

 

tween control valve

 

and remove foreign

 

 

and burner

 

matter

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

ing statement at

 

leaks (see Checking Gas

 

 

top of page

 

Connections, page 15)

 

 

 

 

 

Moisture/condensation

1.

Not enough combus-

1.

Refer to Air for Com-

noticed on windows

 

tion/ventilation air.

 

bustion and Ventilation

 

 

 

 

requirements (page 5)

101805

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Product Identification Local CodesUnpacking ProductAIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterCeiling Floor16 3/ 4 RP30C CGP18CInstalling Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS Qualified service person must connect heater to gas supplySupply Follow all local codesPressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingHeater What to do if YOU Smell GASOperating Heater PilotOperating InspectingBurner Pilot Flame PatternInspecting Burner Burner Flame PatternCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting Trouble FromIng statement at TopTechnical Service Service HintsRP30C CGP18C Replacement Parts Centrals Parts Under WarrantyParts Not Under Warranty Accessories Manual ShutoffFloor Mounting RP30C RP30C Parts List KEY Part Number Description QTYCGP18C CGP18C Parts List Warranty Information Limited Warranty Comfort Glow VENT-FREE Heaters

RP30C, CGP18C specifications

Desa RP30C and CGP18C are two innovative models in the range of residential heat and air solutions designed to enhance home comfort while promoting energy efficiency. Both units stand out due to their advanced features, reliable technology, and user-friendly characteristics.

The Desa RP30C is a powerful, high-efficiency propane heater that delivers exceptional warmth and comfort. It is designed for spaces up to 1,000 square feet, making it suitable for various applications, including homes, workshops, and garages. This heater operates quietly and has an adjustable thermostat that allows users to maintain their desired temperature easily. The RP30C features a durable construction, with a robust chassis and a sleek design that integrates well into different settings.

One of the main highlights of the RP30C is its safety features, which include an automatic shut-off mechanism in case of overheating, ensuring user peace of mind. Additionally, it utilizes a catalytic combustion process that not only maximizes heat production but also minimizes pollutant emissions, making it an environmentally responsible choice.

On the other hand, the CGP18C is a portable gas-powered generator designed for convenience and reliability during power outages or outdoor activities. With an 18,000-watt peak output, this generator can power multiple appliances efficiently. It is built to withstand various environmental conditions, featuring a weather-resistant casing and solid wheels for easy mobility.

The CGP18C employs advanced inverter technology that ensures clean and stable power, making it safe for sensitive devices such as computers and medical equipment. Its user-friendly control panel simplifies operation, while a built-in fuel gauge allows users to monitor their remaining fuel levels effectively. Moreover, the generator is equipped with multiple outlet options, accommodating various plug types to meet diverse power needs.

Both the Desa RP30C and CGP18C exemplify modern engineering, combining functionality, efficiency, and ease of use. They are ideal for anyone seeking effective heating solutions or dependable power generation, making them essential additions for home and outdoor use. With these products, users can enjoy enhanced comfort and reliability in their daily lives.