Desa CFS18PRA, VS24PRA, VS30PRA, VS18PRA installation manual See Wiring Diagram

Page 20

DESA INTERNATIONAL

UNVENTED PROPANE/LP GAS LOG HEATER

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

One or both burners do not light after ODS/

1.

Inlet gas pressure is too low

1.

Contact local propane gas company

pilot is lit

2.

Burner orifice(s) clogged

2.

Clean burner(s) (see Cleaning and Main-

 

 

 

 

tenance, page 18) or replace burner

 

 

 

 

orifice(s)

 

3.

Mislocated crossover tube

3.

Contact qualified service person

 

4.

Burner orifice(s) diameter is too small

4.

Replace burner orifice(s)

 

5.

Selector in OFF position

5.

Put selector in ON position

 

6.

Wire disconnected from gas control

6.

See Wiring Diagram, page 24

 

 

 

 

 

Delayed ignition of one or both burners

1.

Manifold pressure is too low

1.

Contact local propane gas company

 

2.

Burner orifice(s) clogged

2.

Clean burner(s) (see Cleaning and Main-

 

 

 

 

tenance, page 18) or replace burner

 

 

 

 

orifice(s)

 

3.

Mislocated crossover tube

3.

Contact qualified service person

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 18) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas control defective

3.

Replace gas control

 

 

 

 

 

Yellow flame in front burner during burner

1.

Not enough air

1.

Check burner(s) for dirt and debris. If

combustion

 

 

 

found, clean burner(s) (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

2.

Gas control defective

2.

Replace gas control

 

 

 

 

 

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burners are lit

 

when burners are cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burners until air is removed

 

 

 

 

from line. Have gas line checked by lo-

 

 

 

 

cal natural gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see pages 7 through 9)

 

4.

Dirty or partially clogged burner

4.

Clean burners (see Cleaning and Main-

 

 

orifice(s)

 

tenance, page 18) or replace burner

 

 

 

 

orifice(s)

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Remote does not function

1. Battery is not installed. Battery power

 

is low

1.Replace 9-volt batteries in receiver and remote control

www.desatech.com

20

104417

Image 20
Contents Desa International What to do if YOU Smell GASSafety Information Desa International Unvented PROPANE/LP GAS LOG HeaterProduct Features Optional Remote Control AccessoriesUnpacking Product IdentificationAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ClearancesCheck GAS Type Vent-Free Operation OnlyIf Not Using Mantel If Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Logs Installing Front Log #1Lighting Instructions For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure To Turn OFF GAS to ApplianceShutting Off Heater Shutting Off Burners Only pilot stays litOptional Remote Operation Thermostat Control OperationGhrc Operation Ghrct OperationFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Cleaning and Maintenance Replacement PartsTroubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Gas leak. See Warning statement AboveIllustrated Parts Breakdown Variable Control CFS18PRA, VS18PRA VS24PRA, VS30PRAParts List CFS18PRA, VS18PRA VS24PRA, VS30PRASpecifications Wiring DiagramTechnical Service Service HintsAccessories Warranty Information