Desa CFS18PRA Minimum Noncombustible Material Clearances, If Not Using Mantel If Using Mantel

Page 8

DESA INTERNATIONAL

UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 10).

Minimum Noncombustible Material Clearances

If Not Using Mantel

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9, for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. If noncombustible mate- rial is less than 12", you must install the fireplace hood accessory (24" and 30" mod- els only). See Figure 5 for minimum clear- ances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

 

Material Distance (A)

Requirements for Safe Installation

12" or more

Noncombustible material OK.

Between 8" and 12"

Install fireplace hood accessory (GA6050, GA6052,

 

or GA6053 see Accessories, page 25).

Less than 8"

Noncombustible material must be extended to at

 

least 8". See Between 8" and 12", above.

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

8

104417

Image 8
Contents Desa International What to do if YOU Smell GASSafety Information Desa International Unvented PROPANE/LP GAS LOG HeaterProduct Features Optional Remote Control AccessoriesUnpacking Product IdentificationAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ClearancesCheck GAS Type Vent-Free Operation OnlyIf Not Using Mantel If Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Logs Installing Front Log #1Lighting Instructions For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure To Turn OFF GAS to ApplianceShutting Off Heater Shutting Off Burners Only pilot stays litOptional Remote Operation Thermostat Control OperationGhrc Operation Ghrct OperationFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Cleaning and Maintenance Replacement PartsTroubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Gas leak. See Warning statement AboveIllustrated Parts Breakdown Variable Control CFS18PRA, VS18PRA VS24PRA, VS30PRAParts List CFS18PRA, VS18PRA VS24PRA, VS30PRASpecifications Wiring DiagramTechnical Service Service HintsAccessories Warranty Information