Desa BY100CEB, BY70CEB, BY150CEB, BY35CEB Troubleshooting, Observed Fault Possible Cause Remedy

Page 7

OWNER’S MANUAL

TROUBLESHOOTING

WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 10.

off heater after a short period of time.

2.

Dirty air output, air intake, and lint filters

2.

See Air Output, Air Intake and Lint Fil-

 

 

 

 

ters, page 10.

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 8.

 

4.

Dirt in nozzle

4.

See Nozzle, page 11.

 

5.

Dirty photocell lens

5.

Clean photocell lens.

 

6.

Bad flame-out control

6.

Replace flame-out control.

 

 

 

 

 

Heater will not ignite, but motor runs for a

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 10.

short period of time.

2.

Carbon deposits on spark plug and/or

2.

See Spark Plug, page 9.

 

 

improper gap

 

 

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 8.

 

4.

Dirt in nozzle

4.

See Nozzle, page 11.

 

5.

Water in fuel tank

5.

Drain and flush fuel tank with clean

 

 

 

 

kerosene. See Storing, Transporting, or

 

 

 

 

Shipping, page 6.

WARNING: High voltage!

6.Electronic ignitor not grounded (earthed)

7.Bad electronic ignitor

6.Make sure electronic ignitor mounting is tight.

7.Replace electronic ignitor.

Motor does not start when heater is plugged 1.

Flame-out control not reset

1.

Reset flame-out control button, see Fig-

in, fan rotates slowly or does not turn.

 

 

ures 5 and 6, page 5.

2.

Binding pump rotor

2.

If fan is hard to turn, see Pump Rotor,

 

 

 

page 12.

103618

7

Image 7
Contents Portable Forced AIR Heaters Portable Forced AIR Heaters Safety InformationUnpacking Product IdentificationTools Needed AssemblyFuels VentilationTo Stop Heater Extension Cord Wire Size RequirementsTheory Operation To Start HeaterHow Often How To Preventative MaintenanceStoring TRANSPORTING, or Shipping ScheduleObserved Fault Possible Cause Remedy Troubleshooting35/70,000 Btu/Hr Models Service ProceduresUpper Shell Removal Fuel Filter70/100,000 Btu/Hr Models Spark Plug35,000 Btu/Hr Model 70/100/150,000 Btu/Hr ModelsAir Output, Air Intake, and Lint Filters Pump Pressure AdjustmentRemoving Air and Fuel Line Hoses, 35,000 Btu/Hr Model NozzlePump Rotor Procedure if rotor is bindingWiring Diagrams SpecificationsFan Illustrated Parts Breakdown Motor and Pump Assembly35,000 Btu/Hr Model Desired part Parts ListMotor and Pump Assembly Burner Head Assembly70,000 Btu/Hr Model FHPF3-5C 100,000 Btu/Hr Model Lock Washer, #10 HA3019 Photocell Assembly 150,000 Btu/Hr Model Lock Washer, #10 099229-01 Photocell Bracket Wheels Handles Accessories100,000 150,000 EC Conformity Declaration SGB Youngman EC Conformity DeclarationWarranty and Repair Service