Desa BY70CEB, BY150CEB, BY35CEB, BY100CEB owner manual Pump Rotor, Procedure if rotor is binding

Page 12

R

PORTABLE FORCED AIR HEATERS

SERVICE

PROCEDURES

Continued

Pump Rotor

(Procedure if rotor is binding)

1.Remove upper shell (see page 8).

2.Remove filter end cover screws using 5/16" nut-driver.

3.Remove filter end cover and air filters.

4.Remove pump plate screws using 5/16" nut-driver.

5.Remove pump plate.

6.Remove rotor, insert, and blades.

7.Check for debris in pump. If debris is found, blow out with compressed air.

8.Install insert and rotor.

9.Check gap on rotor. Adjust to .076/.101 mm (.003"/.004") if needed (see Fig- ure 27).

Note: Rotate rotor one full turn to insure the gap is .076/.101 mm (.003"/.004") at tight- est position. Adjust if needed.

10.Install blades, pump plate, air filters, and filter end cover.

11.Replace fan guard and upper shell.

12.Adjust pump pressure (see page 10).

Note: If rotor is still binding, proceed as follows.

13. Perform steps 1 through 6 above.

BladeAir

Pump Intake

Plate Filter

Filter End

Cover

Fan Guard

Insert

Rotor

Air Output

Filter

Figure 25 - Rotor Location, 35/70,000 Btu/Hr Models

Blade Pump

Plate

Air Intake Filter

Filter End

Cover

Fan Guard

Insert

Rotor

Air Output

Filter

Figure 26 - Rotor Location, 100/150,000 Btu/Hr Models

14.Place fine grade sandpaper (600 grit) on flat surface. Sand rotor lightly in “figure 8” motion four times (see Fig- ure 28).

15.Reinstall insert and rotor.

16.Perform steps 10 through 12 above.

Gap Adjusting Screw

Blade

Rotor

Gap Adjusting Screw

.076/.101 mm (.003"/.004") Gap Measured With Feeler Gauge

Sandpaper

Figure 27 - Gap Adjusting Screw

Locations

Figure 28 - Sanding Rotor

12

103618

Image 12
Contents Portable Forced AIR Heaters Safety Information Portable Forced AIR HeatersProduct Identification UnpackingAssembly FuelsVentilation Tools NeededExtension Cord Wire Size Requirements Theory OperationTo Start Heater To Stop HeaterPreventative Maintenance Storing TRANSPORTING, or ShippingSchedule How Often How ToTroubleshooting Observed Fault Possible Cause RemedyService Procedures Upper Shell RemovalFuel Filter 35/70,000 Btu/Hr ModelsSpark Plug 35,000 Btu/Hr Model70/100/150,000 Btu/Hr Models 70/100,000 Btu/Hr ModelsPump Pressure Adjustment Air Output, Air Intake, and Lint FiltersNozzle Removing Air and Fuel Line Hoses, 35,000 Btu/Hr ModelProcedure if rotor is binding Pump RotorSpecifications Wiring DiagramsFan Motor and Pump Assembly Illustrated Parts Breakdown35,000 Btu/Hr Model Parts List Desired partBurner Head Assembly Motor and Pump Assembly70,000 Btu/Hr Model FHPF3-5C 100,000 Btu/Hr Model Lock Washer, #10 HA3019 Photocell Assembly 150,000 Btu/Hr Model Lock Washer, #10 099229-01 Photocell Bracket Accessories Wheels Handles100,000 150,000 EC Conformity Declaration EC Conformity Declaration SGB YoungmanWarranty and Repair Service