Lincoln Electric SVM158-A Visual Inspection, Capacitor Discharge Procedure, Routine Maintenance

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 40
Image 40

D-2

D-2

MAINTENANCE

VISUAL INSPECTION

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

WARNING

Have qualified personnel do the maintenance work. Always use the greatest care when working near moving parts.

Do not put your hands near the cooling blower fan. If a problem cannot be corrected by following the instructions, take the machine to the nearest Lincoln Field Service Shop.

-----------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

------------------------------------------------------------------------

EXPLODING PARTS can cause injury.

• Failed parts can explode or cause other parts to explode when power is applied.

Always wear a face shield and long sleeves when servicing.

------------------------------------------------------------------------

See additional warning information throughout this Operator’s Manual.

------------------------------------------------------------------------

CAPACITOR DISCHARGE PROCEDURE

1.Obtain a power resistor (25 ohms, 25 watts).

2.Hold resistor body with electrically insulated glove. DO NOT TOUCH TERMINALS. Connect the resis- tor terminals across the two studs in the position shown. Hold in each position for 1 second. Repeat for all four capacitors.

Clean interior of machine with a low pressure air stream. Make a thorough inspection of all compo- nents. Look for signs of overheating, broken leads or other obvious problems. Many problems can be uncovered with a good visual inspection.

ROUTINE MAINTENANCE

1.Every 6 months or so the machine should be cleaned with a low pressure airstream. Keeping the machine clean will result in cooler operation and higher reliability. Be sure to clean these areas:

All printed circuit boards

Power switch

Main transformer

Input rectifier

Auxiliary Transformer

Reconnect Switch Area

Fan (Blow air through the rear louvers)

2.Examine the sheet metal case for dents or breakage. Repair the case as required. Keep the case in good condition to insure that high voltage parts are protected and correct spacings are maintained. All external sheet metal screws must be in place to insure case strength and electrical ground continuity.

PERIODIC MAINTENANCE

Overload Protection

The machine is electrically protected from producing high output currents. Should the output current exceed 430A, an electronic protection circuit will reduce the current to approximately 100A. The machine will continue to produce this low current until the protection circuit is reset. Reset occurs when the output load is removed.

Return to Section TOC

Return to Master TOC

RESISTOR

CAPACITOR￿

TERMINALS

3.Use a DC voltmeter to check that voltage is not present across the terminals on all four capaci- tors.

Thermal Protection

Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating. If excessive operating temperature should occur, the thermostat will prevent output voltage or current. The meter will remain energized during this time.

Thermostats are self-resetting once the machine cools sufficiently. If the thermostat shutdown was caused by excessive output or duty cycle and the fan is operating normally, the Power Switch may be left on and the reset should occur within a 15 minute peri- od.

V350-PRO

Page 40
Image 40
Lincoln Electric SVM158-A Visual Inspection, Capacitor Discharge Procedure, Routine Maintenance, Periodic Maintenance