7A. ADVANCED PROCESS PANEL

(See Figure B.2)

To program Welding modes. SELECT knob is used to Scroll through all Welding modes. The MEMORY but- ton is used to store and access Welding modes into locations M1 thru M8.

Modes:

In addition to the 5 welding modes described in SEC- TION 7, the Advanced Process Panel allows you to select the Following additional modes.

Power Mode

In the Power Mode;

The work point will be in the Volts window. The Amp window will have CP displayed indicating Constant Power. Once current starts flowing and during the 5 second “Hold” feature the displays will show Volts and Amps respectively. Refer to the detailed expla- nation at the end of this section.

Gouge

Air Carbon Arc Cutting (CAC-A) is a physical means of removing base metal or weld metal by using a car- bon electrode, an electric arc and compressed air.

Pulsed Modes In Pulse Modes;

The work point will be in the Amps window and should be set close to the wire feed speed of the wire feeder in inches per minute. The Volts window will have SPd displayed indicating Wire Feed Speed. Once current starts flowing and during the 5 second “Hold” feature the displays will show amps and volts.

Pulse Mode features that are displayed while select- ing a Welding pulse mode are listed below;

Steel - .030, .035, .045, .052 – Argon Blends Stainless Steel - .030, .035, .045 – Argon Blends & Helium/Argon Blends

Aluminum - .035, 3/64, 1/16 – 4043 & 5356 Metal Core - .045, .052 – Argon Blends Nickel - .035, .045 – Argon/Helium blends

Refer to the detailed explanation at the end of this section.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

ADVANCED PROCESS PANEL VERSION

FIGURE B.2

OUTPUT KNOB

AMPS

VOLTS

CONTROL

 

WELD TERMINALS

REMOTE

 

REMOTE

LOCAL

OUTPUT

ON

 

 

SELECT

 

SELECT

MEMORY

SELECT

SELECT

ADJUST

MEMORY BUTTON (M1 THRU M8)

SELECT KNOB (SCOLLS WELDING PROCESSES)

7A

ADJUST KNOB

(0 THRU 10-HOT START) (-10 THRU 0 AND

0 THRU +10-ARC CONTROL)

SELECT BUTTON

(HOT START OR ARC CONTROL)