TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS

 

 

The V350-Pro does not have weld-

1. Make sure the reconnect switch

1.

Check the reconnect switch and

ing output. The displays are lit.

is configured correctly for the

 

associated leads for loose or

 

input voltage applied.

 

faulty connections. See the

 

 

 

wiring diagram.

 

2. Make sure the Weld Terminals

2.

Perform the Main Switch

 

Select is ON. If the problem is

 

 

Board Test.

 

solved the remote control

 

 

 

 

 

device or associated circuitry

3.

Perform the Power Board

 

may be faulty. See the wiring

 

 

Test.

 

diagram.

 

 

 

 

 

3. Put the Control Select in the

4.

Perform the Output Diode

 

 

Module Test.

 

Local position. If the problem is

 

 

 

 

 

solved the remote control

5.

The control board may be faulty.

 

device or associated circuitry

6.

The input filter capacitors may

 

may be faulty.

 

 

be faulty. Check and replace if

 

 

 

 

4. If an error code is displayed see

 

necessary.

 

 

 

 

Fault Code Explanations.

7.

The remote board may be

 

 

 

 

 

faulty.

 

 

 

 

The V350-Pro will not produce full

1. The input voltage may be too

1.

Perform the Output Rectifier

output.

low, limiting the output capabili-

 

Test.

 

ty of the machine. Make cer-

 

 

 

tain the input voltage is correct

2.

Perform the Main Switch

 

for the machine and the recon-

 

Board Test.

 

nect switch and jumper lead

 

 

 

configuration.

3.

Perform the Power Board

 

 

 

Test.

 

2. The welding current may be too

 

 

 

high . The machine will fold

4.

Perform the Current

 

back to 100 amps if the weld-

 

Transducer Test.

 

ing current exceeds 450 amps.

 

 

 

 

5.

If the preset function is not

 

3. Make sure the machine is in

 

performing properly the status

 

"Local" output control.. If the

 

panel board or the output

 

problem is resolved the Remote

 

control may be faulty.

 

control board or the external

 

 

 

remote control unit may be

6.

The control board may be

 

faulty.

 

faulty.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353(WELD).

V350-PRO

Page 55
Image 55
Lincoln Electric SVM158-A service manual Board Test, Fault Code Explanations, Perform the Output Rectifier, Transducer Test