F-12

TROUBLESHOOTING & REPAIR

F-12

 

 

 

 

FAULT CODES

DESCRIPTION/

CORRECTIVE

SERVICE FACILITY

 

 

DEFINITION

ACTION

CORRECTIVE

 

 

ACTION

 

 

 

 

39

Electrical "glitch" on the

Possibly caused by an

Perform the Main Switch

 

 

primary over current fault

external electrical

Board Test.

 

 

detector circuit.

"noise" or signal level.

Perform the Power

 

 

 

Make sure the V350-Pro

 

 

 

is grounded correctly.

Board Test.

 

 

 

The machine is self

There may be a problem

 

 

 

clearing when

 

 

 

condition ceases.

with the primary current

 

 

 

 

sensors (CT) located on

 

 

 

 

the main switch board.

 

 

 

 

See the wiring diagram.

 

 

 

 

The control board may

 

 

 

 

be faulty.

43

Capacitor banks "A"

Make sure the recon-

There may be a problem

 

(lower) and "B"(upper)

nect switches are con-

with the V/F signals from

 

are not balanced.

figured for the input

the main switch board to

 

 

voltage being applied to

the control board.

 

 

the machine. The

Perform the Main Switch

 

 

machine is self-clearing

 

 

when

Board Test.

 

 

condition ceases.

The capacitor(s) may be

 

 

 

 

 

 

faulty. Check and

 

 

 

replace if necessary.

44

The machine has

Make sure the V350-Pro

Perform the Power

 

detected a fault in the

is grounded correctly.

Board Test.

 

central processing unit

The machine is self

The control board or

 

(CPU).

clearing when

 

 

condition ceases.

associated wiring may be

 

 

 

faulty. See the wiring

 

 

 

diagram.

NOTE: If more than one fault message is being displayed, perform all the checks for the faults