TROUBLESHOOTING & REPAIR | ||||
|
|
| ||
| FAULT CODES | DESCRIPTION/ | CORRECTIVE | SERVICE FACILITY |
|
| DEFINITION | ACTION | CORRECTIVE |
|
| ACTION | ||
|
|
|
| |
39 | Electrical "glitch" on the | Possibly caused by an | Perform the Main Switch | |
|
| primary over current fault | external electrical | Board Test. |
|
| detector circuit. | "noise" or signal level. | Perform the Power |
|
|
| Make sure the | |
|
|
| is grounded correctly. | Board Test. |
|
|
| The machine is self | There may be a problem |
|
|
| clearing when | |
|
|
| condition ceases. | with the primary current |
|
|
|
| sensors (CT) located on |
|
|
|
| the main switch board. |
|
|
|
| See the wiring diagram. |
|
|
|
| The control board may |
|
|
|
| be faulty. |
43 | Capacitor banks "A" | Make sure the recon- | There may be a problem |
| (lower) and "B"(upper) | nect switches are con- | with the V/F signals from |
| are not balanced. | figured for the input | the main switch board to |
|
| voltage being applied to | the control board. |
|
| the machine. The | Perform the Main Switch |
|
| machine is | |
|
| when | Board Test. |
|
| condition ceases. | The capacitor(s) may be |
|
|
| |
|
|
| faulty. Check and |
|
|
| replace if necessary. |
44 | The machine has | Make sure the | Perform the Power |
| detected a fault in the | is grounded correctly. | Board Test. |
| central processing unit | The machine is self | The control board or |
| (CPU). | clearing when | |
|
| condition ceases. | associated wiring may be |
|
|
| faulty. See the wiring |
|
|
| diagram. |
NOTE: If more than one fault message is being displayed, perform all the checks for the faults