F-11

TROUBLESHOOTING & REPAIR

F-11

 

 

 

 

FAULT CODES

DESCRIPTION/

CORRECTIVE

SERVICE FACILITY

 

 

DEFINITION

ACTION

CORRECTIVE

 

 

ACTION

 

 

 

 

35

Capacitor bank

Make sure the reconnect

There may be a problem

 

 

"B"(lower) is over

switches are configured

with the V/F signals from

 

 

voltage.

for the input voltage

the main switch board to

 

 

 

being applied to the

the control board.

 

 

 

machine. The machine

Perform the Main Switch

 

 

 

is self-clearing when

 

 

 

condition ceases.

Board Test.

 

 

 

 

Perform the Power

 

 

 

 

Board Test.

 

 

 

 

The control board may

 

 

 

 

be faulty.

37

The soft start

Turn the machine off and

There may be a problem

 

function failed.

back on to reset the

with the V/F signals from

 

 

machine.

the main switch board to

 

 

 

the control board.

 

 

 

Perform the Main Switch

 

 

 

Board Test.

 

 

 

Perform the Power

 

 

 

Board Test.

 

 

 

The control board may

 

 

 

be faulty.

NOTE: If more than one fault message is being displayed, perform all the checks for the faults

before replacing the printed circuit board