TROUBLESHOOTING & REPAIR | ||||
|
|
| ||
| FAULT CODES | DESCRIPTION/ | CORRECTIVE | SERVICE FACILITY |
|
| DEFINITION | ACTION | CORRECTIVE |
|
| ACTION | ||
|
|
|
| |
35 | Capacitor bank | Make sure the reconnect | There may be a problem | |
|
| "B"(lower) is over | switches are configured | with the V/F signals from |
|
| voltage. | for the input voltage | the main switch board to |
|
|
| being applied to the | the control board. |
|
|
| machine. The machine | Perform the Main Switch |
|
|
| is | |
|
|
| condition ceases. | Board Test. |
|
|
|
| Perform the Power |
|
|
|
| Board Test. |
|
|
|
| The control board may |
|
|
|
| be faulty. |
37 | The soft start | Turn the machine off and | There may be a problem |
| function failed. | back on to reset the | with the V/F signals from |
|
| machine. | the main switch board to |
|
|
| the control board. |
|
|
| Perform the Main Switch |
|
|
| Board Test. |
|
|
| Perform the Power |
|
|
| Board Test. |
|
|
| The control board may |
|
|
| be faulty. |
NOTE: If more than one fault message is being displayed, perform all the checks for the faults