Using a 3/8” nut driver remove the two mounting 14. Replace the control board.

 

 

nuts from the top two corners of the control

 

 

board. See Figure F.19.

13. Cut any necessary cable ties.

FIGURE F.19 CONTROL BOARD MOUNTING SCREW LOCATION

Mounting

Nuts (3/8")

Return to Section TOC

Return to Master TOC

15.Replace the two 3/8” mounting nuts at the top two corners of the control board.

16.Replace any previously removed cable ties.

17.Replace plugs #J3, #J4, #J5, #J6, #J7, #J8, #J9, #J10B, and #J10A previously removed.

18.Replace the two screws and their washers from above and below the input power switch.

19.Replace the four screws from around the two welder output terminals on the front of the machine.

20.Replace the two case front mounting screws at the bottom of the front of the machine.

21.Replace the case wraparound cover.

22.Perform the Voltage and Current Calibration

Procedure.