F-9

TROUBLESHOOTING & REPAIR

F-9

 

 

 

 

FAULT CODES

DESCRIPTION/

CORRECTIVE

SERVICE FACILITY

 

 

DEFINITION

ACTION

CORRECTIVE

 

 

ACTION

 

 

 

 

31

Main transformer

Turn the machine off and

Perform the Main Switch

 

 

primary over current

back on to reset the

Board Test.

 

 

 

machine. If condition

Perform the Power

 

 

 

persists, contact an

 

 

 

authorized Lincoln Field

Board Test.

 

 

 

Service Facility.

There may be a problem

 

 

 

 

 

 

 

 

with the primary current

 

 

 

 

sensors (CT) located on

 

 

 

 

the main switch board.

 

 

 

 

See the Wiring diagram

 

 

 

 

The control board may

 

 

 

 

be faulty.

32

Capacitor bank “A”

Make sure the reconnect

There may be a problem

 

(lower) is under

switches are configured

with the V/F signals from

 

voltage

for the input voltage

the main switch board to

 

 

being applied to the

the control board.

 

 

machine. The machine

Perform the Main Switch

 

 

is self clearing when

 

 

condition ceases.

Board Test.

 

 

 

Perform the Power

 

 

 

Board Test.

 

 

 

The control board may

 

 

 

be faulty.

NOTE: If more than one fault message is being displayed, perform all the checks for the faults