F-4

 

 

 

 

F-4

 

TROUBLESHOOTING & REPAIR

 

 

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

Major physical or electrical damage

1. Contact

your local authorized

1. Contact the Lincoln Electric

is evident when the sheet metal

Lincoln

Electric Field Service

Service Department,

 

 

cover is removed.

Facility for technical assistance.

1-800-833-9353(WELD).

 

 

 

 

 

 

 

 

 

The machine is dead—no output—

1. Make sure the input line/breaker

1. Perform

the

Auxiliary

 

no displays.

switch is in the ON position.

Transformer Test.

 

 

 

 

2. Check the 3.5 amp circuit break-

2. Perform the Power Board Test.

 

 

er (CB3). Reset if tripped.

 

 

 

 

 

 

 

 

3. Check the main input line fuses.

3. The control rectifier and or asso-

 

 

ciated filter capacitor

(C5) may

 

 

If open , replace.

 

 

be faulty. Check and replace as

 

 

4. Check the 3.5 amp circuit break-

 

 

necessary.

 

 

 

 

 

er (CB2). Reset if tripped.

 

 

 

 

 

 

5. Check the 6 amp circuit breaker

4. Perform

The SPI

Cable

 

 

Resistance and Voltage Test.

 

 

(CB1). Reset if tripped.

 

 

 

 

 

 

 

 

6. Make sure the reconnect switch

5. The Control Board may be faulty.

 

 

and jumper lead is configured

 

 

 

 

 

 

correctly for the applied input

 

 

 

 

 

 

voltage.

 

 

 

 

 

7.If the machine is being operated with single phase input voltage make sure the red lead is not connected. See the Installation Section.

The main input fuses (or breaker)

1. Make certain the fuses or break-

1.

Check the reconnect

switches

repeatedly fail.

ers are sized properly.

 

and associated wiring.

See the

 

2. Make sure the reconnect switch

 

Wiring Diagram.

 

 

 

 

 

Input

Rectifier

 

and jumper lead is configured

2.

Perform

the

 

correctly for the applied input

 

Test.

 

 

 

 

voltage.

3.

Perform the Main Switch Board

 

 

 

3. The welding procedure may be

 

Test.

 

 

 

 

drawing too much input current

4.

Perform

the

Output Diode

 

or the duty cycle may be too

 

 

Module Test.

 

 

 

high. Reduce the welding cur-

 

 

 

 

 

 

 

 

 

 

rent and /or reduce the duty

5.

The Input Filter Capacitors may

 

cycle.

 

be faulty.

Check, and if any are

 

 

 

faulty replace all four.

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353(WELD).