TROUBLESHOOTING & REPAIR | ||||
|
|
| ||
| FAULT CODES | DESCRIPTION/ | CORRECTIVE | SERVICE FACILITY |
|
| DEFINITION | ACTION | CORRECTIVE |
|
| ACTION | ||
|
|
|
| |
47 | Electrical "glitch" on the | Possibly caused by an | There may be a problem | |
|
| V/F signals from the main | external electrical | with the V/F signals from |
|
| switch board to the | "noise" or signal level. | the main switch board to |
|
| control board. | Make sure the | the control board. |
|
|
| is grounded correctly. | Perform the Main Switch |
|
|
| The machine is self | |
|
|
| clearing when condition | Board Test. |
|
|
| ceases. | Perform the Power |
|
|
|
| |
|
|
|
| Board Test. |
|
|
|
| The control board may |
|
|
|
| be faulty. |
“bad node” “####” | The selected weld mode | Press the Mode Select | If new software was just |
| does not exist in the weld | button to select a | installed, try reinstalling |
| table that is presently | different welding mode. | the software or put the |
| loaded in the machine. |
| original software back. |
|
|
| Perform the Power |
|
|
| Board Test. |
|
|
| Perform the SPI Cable |
|
|
| Resistance and Voltage |
|
|
| Test. |
|
|
| The control board may |
|
|
| be faulty. |
NOTE: If more than one fault message is being displayed, perform all the checks for the faults