TOC
TOC
TROUBLESHOOTING & REPAIR
INPUT RECTIFIER TEST (CONTINUED)
Return to Section
Return to Master
TEST PROCEDURE
1.Remove input power to the
2.Using a 5/16” nut driver, remove the case wraparound cover.
3.Perform the Capacitor Discharge Procedure detailed earlier in this section.
4.Locate the input rectifier and associated leads. See Figure F.3.
5.Carefully remove the silicone sealant from leads 207, 207A, and 209.
6.Using a phillips head screwdriver, remove leads 207, 207A, and 209 from the input rectifier.
7.Use the analog ohmmeter to perform the tests detailed in Table F.2. See the Wiring Diagram.
8.Visually inspect the three MOV’S for damage (TP1,TP2,TP3). Replace if nec- essary.
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Figure F.3 Input Rectifier
Small Lead "H1"
ToAuxiliary Transformer3/16" ALLEN
BOLTS
C
B
#207
#207A
A | #209 |
Small Lead "A"
FRONT ToCircuit Breaker