Lincoln Electric SVM158-A service manual Input Rectifier Test, Test Procedure

Models: SVM158-A

1 167
Download 167 pages 56.76 Kb
Page 72
Image 72

TOC

TOC

F-22

F-22

TROUBLESHOOTING & REPAIR

INPUT RECTIFIER TEST (CONTINUED)

Return to Section

Return to Master

TEST PROCEDURE

1.Remove input power to the V350-PRO machine.

2.Using a 5/16” nut driver, remove the case wraparound cover.

3.Perform the Capacitor Discharge Procedure detailed earlier in this section.

4.Locate the input rectifier and associated leads. See Figure F.3.

5.Carefully remove the silicone sealant from leads 207, 207A, and 209.

6.Using a phillips head screwdriver, remove leads 207, 207A, and 209 from the input rectifier.

7.Use the analog ohmmeter to perform the tests detailed in Table F.2. See the Wiring Diagram.

8.Visually inspect the three MOV’S for damage (TP1,TP2,TP3). Replace if nec- essary.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Figure F.3 Input Rectifier

Small Lead "H1"￿

To￿Auxiliary Transformer3/16" ALLEN ￿

BOLTS

C

B

#207

#207A￿

￿

￿

￿

￿

A

#209

Small Lead "A"￿

FRONT￿ To￿Circuit Breaker

REAR

V350-PRO

Page 72